LAKEWOOD, CO —
OSHA Inspection: EXCELLENCE CONSTRUCTION LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EXCELLENCE CONSTRUCTION LLC in 3277 S NEWCOMBE, LAKEWOOD, CO 80227 (NAICS 238130). OSHA activity number 347007676.
Where did this inspection happen?
- Establishment
- EXCELLENCE CONSTRUCTION LLC
- Site address
- 3277 S NEWCOMBE
- City
- LAKEWOOD
- State
- CO
- ZIP
- 80227
- Mailing
- 4156 S DALE CT, ENGLEWOOD, CO 80110
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $4688.00 · Current $4688.00
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On or before 10/3/23 the employer did not ensure that employees framing a porch roof of a new single family home worked with fall protection. This condition exposed employees to fall hazards of 12.5 feet.
Recent events (1)
- — Z (S) $4688
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $3349.00 · Current $3349.00
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On or before 10/3/23 the employer did not ensure that employees accessing the roof adjacent to the porch roof of a new single family home used a ladder where the rails extended at least 3 feet past the edge of the working platform. This condition exposed employees to fall hazards of 12.5 feet.
Recent events (1)
- — Z (S) $3349
More inspections at EXCELLENCE CONSTRUCTION LLC
ATLANTA, GA—2025-05-06
EXCELLENCE CONSTRUCTION, LLC
View EXCELLENCE CONSTRUCTION LLC's full OSHA safety record →
More inspections in this industry (NAICS 238130)
ENCINITAS, CA—2026-07-13
LOU RIDDLE CONSTRUCTION
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
SLINGER, WI—2026-07-10
RAMIREZ HOME BUILDERS LLC
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
HIGHLANDS RANCH, CO—2026-07-08
HOWELL CONSTRUCTION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347007676.