LAKEWOOD, NJ —
OSHA Inspection: BEST FLOORING SOLUTIONS INC
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of BEST FLOORING SOLUTIONS INC in 1105 EAST COUNTYLINE ROAD, LAKEWOOD, NJ 08701 (NAICS 238330). OSHA activity number 347031601.
Where did this inspection happen?
- Establishment
- BEST FLOORING SOLUTIONS INC
- Site address
- 1105 EAST COUNTYLINE ROAD
- City
- LAKEWOOD
- State
- NJ
- ZIP
- 08701
- Mailing
- 40 CHRISTMAS HILL ROAD, AIRMONT, NY 10952
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238330
- Employees
- 11
- Ownership type
- A
Citations
11 citations on file for this inspection.
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $2765.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) 1105 East Countyline Rd, Lakewood, NJ: On or about 10/13/2023, the employer did not establish or implement a written Respiratory Protection when employees were provided and required to wear respirators, including but not limited to, 3M 6500 half face elastomeric respirators. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $1000
- — C (S) $2765
- — Z (S) $2765
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) 1105 East Countyline Rd, Lakewood, NJ: On or about 10/13/2023, employees who were provided and required to wear respirators, including but not limited to, 3M 6500 half face elastomeric respirators, were not medically evaluated for respirator use prior to using the respirator. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.134 K01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(k)(1): The employer did not provide respirator training that would ensure each employee could demonstrate knowledge of items in section (i)-(vii): a) 1105 East Countyline Rd, Lakewood, NJ: On or about 10/13/2023, the employer did not provide training to employees who were provided and required to wear 3M 6500 half face elastomeric respirators. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $6452.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer had not developed or implemented a written hazard communication program including the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): a)1105 East Countyline Rd, Lakewood, NJ: On or about 10/13/2023, the employer did not develop or maintain a written hazard communication program for chemicals used by employees in the facility including, but not limited to, Premera QuickSeal and Premera T2 MCM (Class 2 flammables). NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $3000
- — C (S) $6452
- — Z (S) $6452
1910.1200 G01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(1): The employer did not have a safety data sheet in the workplace for each hazardous chemical which they used: a)1105 East Countyline Rd, Lakewood, NJ: On or about 10/13/2023, the employer did not have safety data sheets (SDSs) for chemicals used by employees including, but not limited to, Premera QuickSeal and Premera T2 MCM (Class 2 flammables).
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a)1105 East Countyline Rd, Lakewood, NJ: On or about 10/13/2023, the employer did not provide Hazard Communication training for chemicals used by employees in the including, but not limited to, Premera QuickSeal and Premera T2 MCM (Class 2 flammables). NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $0
- — C (S) $0
- — Z (S) $0
1926.21 B02
- Issued
- Abate by
- Penalty
- Initial $4610.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) 1105 East Countyline Rd, Lakewood, NJ: On or about 10/13/2023, employees were not trained on fire extinguisher use and hazards involved with incipient stage fire fighting. An employee had to use a fire extinguisher after a bucket of a class 2 flammable material ignited. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $1200
- — C (S) $4610
- — Z (S) $4610
1926.152 A01
- Issued
- Abate by
- Penalty
- Initial $4610.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.152(a)(1): Containers other than approved metal safety cans or DOT approved containers were used for the handling and use of flammable liquids in quantities of 5 gallons or less: a) 1105 East Countyline Rd, Lakewood, NJ: On or about 10/13/2023, the employer did not provide metal safety cans or approved containers when employees transferred Premera QuickSeal and Premera T2 MCM (Category 2 Flammables) with flash points of -4�F and <77�F, into 5-gallon plastic buckets. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $1200
- — C (S) $4610
- — Z (S) $4610
1926.152 E02
- Issued
- Abate by
- Penalty
- Initial $4610.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.152(e)(2): The transfer of flammable liquids from one container to another was done when the containers were not electrically interconnected (bonded): a) 1105 East Countyline Rd, Lakewood, NJ: On or about 10/13/2023, containers were not bonded when liquid from 55 gallon drums of Premera QuickSeal and Premera T2 MCM (Category 2 flammables with flash points of -4�F and <77�F) were poured into 5 gallon buckets for use in the workspace. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (4)
- — J (S) $1200
- — J (S) $1200
- — C (S) $4610
1926.152 E03
- Issued
- Abate by
- Penalty
- Initial $4610.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.152(e)(3): Flammable or combustible liquids were not drawn from or transferred into vessels, containers, or tanks within buildings or outside through closed piping systems, from safety cans or by means of devices drawing through the top: a) 1105 East Countyline Rd, Lakewood, NJ: On or about 10/13/2023, employees were not provided effective means to draw or transfer liquids when they used Premera QuickSeal and Premera T2 MCM (Category 2 flammables) with flash points of -4�F and <77�F. Employees tipped 55-gallon drums by hand to dispense the products into 5-gallon buckets. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (4)
- — J (S) $1200
- — J (S) $1200
- — C (S) $4610
1926.152 F03
- Issued
- Abate by
- Penalty
- Initial $6452.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.152(f)(3): Flammable liquids were used where there were open flames or other sources of ignition within 50 feet of the operation: a) 1105 East Countyline Rd, Lakewood, NJ: On or about 10/13/2023, employees used Premera QuickSeal and Premera T2 MCM (class 2 flammables) with flash points of -4�F and <77�F while using a portable electric heater. b) 1105 East Countyline Rd, Lakewood, NJ: On or about 10/13/2023, employees used a heat gun to warm 55 gallon drums containing Premera QuickSeal and Premera T2 MCM (Class 2 flammables) with flash points of -4�F and <77�F. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (3)
- — J (S) $1200
- — C (S) $6452
- — Z (S) $6452
More inspections in this industry (NAICS 238330)
RICHLAND, WA—2026-06-24
WA317991783 - VM CARPET INSTALLATION LLC
WASHINGTON, PA—2026-06-18
CREATIVE FLOOR SOLUTIONS
LEBANON, TN—2026-06-17
MARIA L. CHACON ORELLANA
EVELETH, MN—2026-06-15
111427 - CONTRACT TILE AND CARPET LLC
BERLIN, CT—2026-06-11
JIMENEZ FLOORING LLC
More inspections in NJ
FREEHOLD, NJ—2026-07-10
MARIO & SONS CONSTRUCTION GROUP, LLC
FREEHOLD, NJ—2026-07-10
VACCA ROOFING
FREEHOLD, NJ—2026-07-10
SPECTRA PAINTING, INC
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
FREEHOLD, NJ—2026-07-10
GTN CONSTRUCTION INC
Source