CLARENDON HILLS, IL —
OSHA Inspection: JUAN MARCOS GONZALEZ DBA JUAN MARCOS GONZALEZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JUAN MARCOS GONZALEZ DBA JUAN MARCOS GONZALEZ in 272 COLUMBINE DR., CLARENDON HILLS, IL 60514 (NAICS 238160). OSHA activity number 347063158.
Where did this inspection happen?
- Establishment
- JUAN MARCOS GONZALEZ DBA JUAN MARCOS GONZALEZ
- Site address
- 272 COLUMBINE DR.
- City
- CLARENDON HILLS
- State
- IL
- ZIP
- 60514
- Mailing
- 1445 E. PORT O CALL DR., PALATINE, IL 60074
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Penalty
- Initial $4018.00 · Current $4018.00
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. On or about October 24, 2023, Employees were exposed to fall hazards in approximately 8-18 feet while engaged in residential roofing activities. Fall protection was not being utilized while employees were engaged in roof installation and tear-off activities. No abatement certification or documentation is required for this item.
Recent events (1)
- — Z (S) $4018
1926.1053 B01
- Issued
- Penalty
- Initial $2009.00 · Current $2009.00
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grab rail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. On or about October 24, 2023, the portable ladder used to access the roof level did not extend at least three (3') feet above the upper landing surface, thereby exposing employees to fall hazard. No abatement certification or documentation is required for this item.
Recent events (1)
- — Z (S) $2009
1926.503 B01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.503(b)(1): The employer shall verify compliance with paragraph (a) of this section by preparing a written certification record. The written certification record shall contain the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. If the employer relies on training conducted by another employer or completed prior to the effective date of this section, the certification record shall indicate the date the employer determined the prior training was adequate rather than the date of actual training. On or about October 24, 2023, the employer did not certify that employees had been trained to recognize and minimize fall hazards. Employees were exposed to fall hazards in approximately 8-18 feet while performing roof installation activities without using fall protection. No abatement certification or documentation is required for this item.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in IL
DEERFIELD, IL—2026-07-16
JOHN BURNS CONSTRUCTION COMPANY, LLC
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
FRANKLIN PARK, IL—2026-07-16
B & M PLASTIC INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347063158.