PATERSON, NJ —
OSHA Inspection: CENTIV SERVICES CORPORATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CENTIV SERVICES CORPORATION in 75 WOOD STREET, PATERSON, NJ 07524 (NAICS 493110). OSHA activity number 347063844.
Where did this inspection happen?
- Establishment
- CENTIV SERVICES CORPORATION
- Site address
- 75 WOOD STREET
- City
- PATERSON
- State
- NJ
- ZIP
- 07524
- Mailing
- 1500 W 3RD STREET, SUITE 325, CLEVELAND, OH 44113
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 80
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 II
- Issued
- Penalty
- Initial $8873.00 · Current $5324.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): a) Assembly Area: The company energy control procedures did not have specific procedural steps for shutting down and control hazardous energy on equipment such as but not limited to Glue coating machine, Hollow paper drill, Double head tubular riveter machine, Book casing machine, Foil Stamping machine, A Plastic welder/foil printing machine, Menu corner applicator, small foil printing machine, Paper/Board Cutter and Large format UV ink printer, on or about 10/24/2023.
Recent events (3)
- — J (S) $5323.8
- — C (S) $8873
- — Z (S) $8873
1910.147 C06 I
- Issued
- Penalty
- Initial $7098.00 · Current $4259.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Assembly Area: The employer failed to conduct periodic inspections of each energy control procedure at least annually to verify that the specific procedures for equipment were adequate and were being applied correctly, on or about 10/24/2023.
Recent events (3)
- — J (S) $4258.8
- — C (S) $7098
- — Z (S) $7098
1910.212 A01
- Issued
- Penalty
- Initial $12421.00 · Current $7453.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Assembly Area: An employee was exposed to an amputation hazard from the moving parts from the unexpected start up from the Stamping machine, on or about 10/24/2023.
Recent events (3)
- — J (S) $7452.6
- — C (S) $12421
- — Z (S) $12421
1910.303 B07 I
- Issued
- Penalty
- Initial $7098.00 · Current $4259.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment. a) Assembly Area: Employee exposed to an electrical shock from an electrical panel that had a unused opening that was not effectively closed, on or about 10/26/2023. b) Stamping Department: Employees exposed to an electrical shock from the exposed wiring on the electrical box that was missing the cover on the ZEH & Hahnemann Company Stamping machine, on or about 10/26/2023.
Recent events (3)
- — J (S) $4258.8
- — C (S) $7098
- — Z (S) $7098
More inspections in this industry (NAICS 493110)
PORTSMOUTH, VA—2026-07-15
DACS INC
WEST CHESTER, OH—2026-07-14
CRESCENT PARK CORPORATION
WEYMOUTH, MA—2026-07-14
SPEEDX
DUNDALK, MD—2026-07-09
WILLIAMS SCOTSMAN, INC.
ROCK HILL, SC—2026-07-08
77566 - WEST MARINE INC
More inspections in NJ
PERTH AMBOY, NJ—2026-07-16
ENGLERT INC.
RIDGEFIELD, NJ—2026-07-16
COLORITE PLASTICS COMPANY
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
GLASSBORO, NJ—2026-07-15
GLASSBORO WATER & SEWER DEPARTMENT
FLANDERS, NJ—2026-07-15
TRI-STATE QUIKRETE
Source