Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PRECISION TURNED COMPONENTS

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of PRECISION TURNED COMPONENTS in 331 FARNUM PIKE, SMITHFIELD, RI 02917 (NAICS 332710). OSHA activity number 347070195.

Watch Precision Turned Components — free Get an email when a new federal OSHA severe-injury report for Precision Turned Components is published. One employer, no account, unsubscribe in one click.
Site address
331 FARNUM PIKE
City
SMITHFIELD
State
RI
ZIP
02917
Mailing
331 FARNUM PIKE, SMITHFIELD, RI 02917
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
44
Ownership type
A

4 citations on file for this inspection.

1910.134 C01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $11292.00 · Current $5646.00 Reduced

Hazardous substances 2037

29 CFR  1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  (a) Back Finishing Area of the Establishment: On or about October 31, 2023, an employee was engaged in cleaning and degreasing metal parts using Safety-Kleen Premium Solvent while wearing a 3M Half-Face Organic Vapor respirator when the employer had not developed nor implemented a written respiratory protection program.
Recent events (2)
  • — I (S) $5646
  • — Z (S) $11292

1910.134 D01 III

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 2037

29 CFR  1910.134(d)(1)(iii):The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form:  (a) Back Finishing Area of the Establishment: On or about October 31, 2023 the employer did not identify and evaluate employee exposure while they are performing cleaning and degreasing of metal parts using Safety-Kleen Premium Solvent.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 2037

29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:   (a) Back Finishing Area of the Establishment: On or about October 31, 2023 an employee was performing cleaning and degreasing metal parts work using Safety-Kleen Premium Solvent  while wearing a 3M Half-Face Organic Vapor respirator and the employer had not provided a medical evaluation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 2037

29 CFR  1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):    (a) Back Finishing Area of the Establishment: On or about October 31, 2023, the employer did not conduct fit testing for an employee wearing a 3M Half-Face Organic Vapor respirator when engaged in cleaning and degreasing metal parts using Safety-Kleen Premium Solvent.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View PRECISION TURNED COMPONENTS's full OSHA safety record →