WOODVILLE, WI —
OSHA Inspection: WOODVILLE WAREHOUSING & DISTRIBUTING, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WOODVILLE WAREHOUSING & DISTRIBUTING, LLC in 107 HAGEN DRIVE, WOODVILLE, WI 54028 (NAICS 493110). OSHA activity number 347110561.
Where did this inspection happen?
- Establishment
- WOODVILLE WAREHOUSING & DISTRIBUTING, LLC
- Site address
- 107 HAGEN DRIVE
- City
- WOODVILLE
- State
- WI
- ZIP
- 54028
- Mailing
- 107 HAGEN DRIVE, WOODVILLE, WI 54028
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 15
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.37 B02
- Issued
- Abate by
- Penalty
- Initial $2277.00 · Current $1594.00 Reduced
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": (a) Building 107 Aisle 4; The exit door did not contain an exit sign.
Recent events (2)
- — I (S) $1593.9
- — Z (S) $2277
1910.157 E02
- Issued
- Abate by
- Penalty
- Initial $2277.00 · Current $1594.00 Reduced
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: (a) Throughout the establishment; Portable fire extinguishers provided for use were not visually inspected monthly.
Recent events (2)
- — I (S) $1593.9
- — Z (S) $2277
1910.157 G02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting was not provided to all employees upon initial employment, and at least annually thereafter: (a) Throughout the establishment; The employer failed to provide annual training to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.176 B
- Issued
- Penalty
- Initial $3795.00 · Current $2657.00 Reduced
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: (a) Building 470 central warehouse aisle; A tiered, wrapped, and palletized stack of product containing 60 bags and weighing 1,500 pounds was not securely stacked during storage.
Recent events (2)
- — I (S) $2656.5
- — Z (S) $3795
1910.178 Q07
- Issued
- Abate by
- Penalty
- Initial $3795.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed into service and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination was not made at least daily: (a) Throughout the establishment; Forklifts including but not limited to a Raymond model 750-DR32TT forklift (Serial Number 750-19-BC74706) and Crown 5200 series forklift were not inspected daily before being placed into service.
Recent events (2)
- — I (O) $0
- — Z (S) $3795
1910.303 B01
- Issued
- Penalty
- Initial $6250.00 · Current $4063.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: (a) Building 107 electric forklift battery charging area; An Ametek Eclipse II Plus model 105DEC3-18DP (unit #20) battery charging station cord used to charge the battery for a Raymond model 8410 Electric Pallet Truck (unit #39) was damaged and showed exposed conductor wire.
Recent events (2)
- — I (S) $4062.5
- — Z (S) $6250
1910.303 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: (a) Building 107 electric forklift battery charging area; The circuit breaker panel (C 277/480) access door was impeded by an Ametek Eclipse II Plus model 105DEC3-18DP battery charger (unit #20) and a Hawker Life Plus Mod3 model LPM3-48C-180Y battery charger (Serial No. RXI00560404).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G02 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(2)(ii): In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage: (a) Building 107 electric forklift battery charging area; Battery charging stations, including but not limited to a damaged GNB model SCRFLX-18-865T1Z battery charger (unit #18) and a damaged Ametek Eclipse II Plus model 105DEC3-18DP battery charger (unit #20), were not sufficiently protected against physical damage.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 493110)
PORTSMOUTH, VA—2026-07-15
DACS INC
WEST CHESTER, OH—2026-07-14
CRESCENT PARK CORPORATION
WEYMOUTH, MA—2026-07-14
SPEEDX
DUNDALK, MD—2026-07-09
WILLIAMS SCOTSMAN, INC.
ROCK HILL, SC—2026-07-08
77566 - WEST MARINE INC
More inspections in WI
WAUSAU, WI—2026-07-16
MIRON CONSTRUCTION CO. INC.
ELROY, WI—2026-07-15
WABASH NATIONAL SERVICES, L.P.
SUSSEX, WI—2026-07-15
KINGS SUPERIOR CONSTRUCTION LLC
DELAVAN, WI—2026-07-15
TERONOMY BUILDERS, INC.
DELAVAN, WI—2026-07-15
A. GOMEZ CARPENTRY, INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347110561.