Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: FOXCONN INDUSTRIAL INTERNET USA

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FOXCONN INDUSTRIAL INTERNET USA in 12001 BRAUN RD #210,, MOUNT PLEASANT, WI 53177 (NAICS 519190). OSHA activity number 347134322.

Watch Foxconn Industrial Internet USA — free Get an email when a new federal OSHA severe-injury report for Foxconn Industrial Internet USA is published. One employer, no account, unsubscribe in one click.
Site address
12001 BRAUN RD #210,
City
MOUNT PLEASANT
State
WI
ZIP
53177
Mailing
12001 BRAUN RD #210,, MOUNT PLEASANT, WI 53177
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
519190
Employees
951
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $13711.00 · Current $10000.00 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  (a) On or about November 30, 2023, and dates prior, the employer did not develop, document and utilize  specific energy control procedures for, but not limited to the Sinvo automated assembly Machine Cells (Line 1 and Line 2 - Wave 3 Pack Out),  that outline the steps for shutting  down, blocking, and isolating mechanical and other energy sources.  This exposed employees to crushing and struck-by hazards.
Recent events (2)
  • — I (S) $10000
  • — Z (S) $13711

1910.147 C06 I

Deleted Serious Gravity 10 1 instance 100 exposed
Issued
Abate by
Penalty
Initial $16131.00 · Current $0.00 Reduced
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  (a) On or about November  30, 2023, and dates prior, the employer did not insure that a periodic inspection of the energy control procedure was conducted at least annually, to ensure the procedure and the requirement of this standard were being followed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $16131

1910.147 C07 I A

Serious Gravity 10 1 instance 20 exposed
Issued
Abate by
Penalty
Initial $16131.00 · Current $8000.00 Reduced
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:   (a) On or about November 30, 2023, and days prior, authorized employee training was not provided to all  maintenance Technicians and other authorized personnel in the recognition of hazardous energy sources, and practices and methods required to safely deenergize machines/equipment, including but not limited to fluid delivery systems, HVAC systems, air compressor systems, and manufacturing machines and systems.
Recent events (2)
  • — I (S) $8000
  • — Z (S) $16131

1910.147 C07 I B

Deleted Serious Gravity 5 1 instance 90 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure:  (a) On or about November 30, 2023, and dates prior, training was not provided to affected personnel in the recognition of hazardous energy sources and the type of energy sources exposed to in the manufacturing operations and while performing job tasks.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 10 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $16131.00 · Current $6000.00 Reduced
29 CFR  1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  (a) On or about November 20, 2023,  at the Sinvo automated assembly machine cell (Line 1 - Wave 3 Pack Out), the employer by-passed the 22  integrated access door interlocks allowing employee(s) to access multiple point of operations to clear jams and to load material, to include but not limited to the energized conveyor, machine part presses and adhesive stations. This exposed employees to struck-by, caught-in and crushing hazards.  (b) On or about November 30, 2023, and days prior, at the Sinvo automated assembly machine cell (Line 2 - Wave 3 Pack Out), the employer by-passed the 22 integrated  access door interlocks allowing employee(s) to access multiple point of operations to clear jams and to load material, to include but not limited to the energized conveyor, machine part presses and adhesive stations. This exposed employees to struck-by, caught-in and crushing hazards.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $16131