OSHA Inspection: YOUNGS ROOFING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of YOUNGS ROOFING LLC in 12711 SUNSET DR, FIRESTONE, CO 80504 (NAICS 238160). OSHA activity number 347148348.

Watch Youngs Roofing LLC — free Get an email when a new federal OSHA severe-injury report for Youngs Roofing LLC is published. One employer, no account, unsubscribe in one click.
Establishment
YOUNGS ROOFING LLC
Site address
12711 SUNSET DR
City
FIRESTONE
State
CO
ZIP
80504
Mailing
60 SOUTH HAVANA STREET SUITE 611, AURORA, CO 80012
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3349.00 · Current $3349.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):      a) Construction Site, 12711 Sunset Dr, Firestone, CO 80504: On or about December 05, 2023, employees were exposed to fall hazards of approximately 20 feet to the ground below installing gutter on the second level of an existing residential home without fall protection.
Recent events (1)
  • — Z (S) $3349

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3349.00 · Current $3349.00
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed:   a) Construction Site, 12711 Sunset Dr, Firestone, CO 80504: On or about December 04, 2023, employees were exposed to fall hazards while using a self-supporting ladder in a manner it was not designed for. The six-foot fiberglass step ladder was a self-supporting ladder being used as a non-self-supporting ladder to install rain gutter on the second level of a residential home.
Recent events (1)
  • — Z (S) $3349

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347148348.