NEW CASTLE, PA —
OSHA Inspection: SUPERIOR FORGE AND STEEL, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SUPERIOR FORGE AND STEEL, INC. in 597 COMMERCE AVENUE, NEW CASTLE, PA 16101 (NAICS 333519). OSHA activity number 347156531.
Where did this inspection happen?
- Establishment
- SUPERIOR FORGE AND STEEL, INC.
- Site address
- 597 COMMERCE AVENUE
- City
- NEW CASTLE
- State
- PA
- ZIP
- 16101
- Mailing
- 597 COMMERCE AVENUE, NEW CASTLE, PA 16101
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333519
- Employees
- 40
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.28 B01 I
- Issued
- Abate by
- Penalty
- Initial $12445.00 · Current $9000.00 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): A.) Superior Forge and Steel, Inc. DBA Superior Forge and Steel Corporation, on or about 11/30/23 and times prior thereto: An employee engaged in grate removal activities of the pit did not utilize fall protection systems to protect against the 12 foot fall hazard. Employee was at edge hooking up grating and employee fell into the pit. Grate removal activities include but are not limited to, putting alloy steel chains on the grating. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation. This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement. IN ADDITION, abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic, or video evidence or abatement or other written records.
Recent events (2)
- — I (S) $9000
- — Z (S) $12445
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $8296.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.147(d):The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): A.) Superior Forge and Steel, Inc. DBA Superior Forge and Steel Corporation, on or about 11/30/2323 and times prior thereto: lockout did not occur prior to employees conducting clean up and chip hopper removal operations associated with the pit area of the Waldrich Roughing Lathe. Cleaning operations include but are not limited to hooking up grates, lifting hoppers out of the pit, and sweeping the pit area. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2500
- — Z (S) $8296
1904.29 B01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1904.29(b)(1):A log of all recordable work-related injuries and illness (OSHA Form 300 or equivalent) was not completed in the detail required by the regulation. A. Superior Forge and Steel, Inc. DBA Superior Forge and Steel Corporation, on or about 8/25/23 and times prior thereto: The recordable injury and/or illness entries on the OSHA 300 Log for the Calendar Year 2023 were not completed as required. In Column F the Recordable case 4 that occurred on 8/25/23 was not descriptive, in that the body part affected, and/or the agent, object, and/or substance that directly injured or made the person ill was not noted/documented. B. Superior Forge and Steel, Inc. DBA Superior Forge and Steel Corporation, on or about 9/20/23 and times prior thereto: The recordable injury and/or illness entries on the OSHA 300 Log for the Calendar Year 2023 were not completed as required. In Column F the Recordable case 5 that occurred on 9/20/23 was not descriptive, in that the body part affected, and/or the agent, object, and/or substance that directly injured or made the person ill was not noted/documented. NO ABATEMENT CERTIFICATION OR DOCUMENATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.22 D01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(d)(1): The employer did not ensure that walking-working surfaces are inspected, regularly and as necessary, and maintained in a safe condition A.) Superior Forge and Steel, Inc. DBA Superior Forge and Steel Corporation, on or about 12/11/23 and times prior thereto: the walking working surface around the pit was not inspected regularly to ensure it was in good condition. The guardrail around the pit that is used as a method of fall protection was missing anchorage bolts. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.145 E02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.145(e)(2):The wording of signs was not easily read and concise. A.) Superior Forge and Steel, Inc. DBA Superior Forge and Steel Corporation, on or about 12/11/23 and times prior thereto: warning signs to restrict entry at the pit area were defaced due to the message being covered by dirt or other materials. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C06 I C
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C):Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected: A.)Superior Forge and Steel, Inc. DBA Superior Forge and Steel Corporation, on or about 12/6/23 and times prior thereto: the employer performed periodic inspections on equipment including but not limited to the Landis Grinder. All authorized employees were not included in the periodic inspection process. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.147 C04 II D
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control. Superior Forge and Steel, Inc. DBA Superior Forge and Steel Corporation, on or about 12/11/23 and times prior thereto: Verification of isolation in energy control procedures for equipment was generic in that it did not identify specific requirements or controls to verify the effectiveness of lockout. Equipment includes, but is not limited to, 42" Waldrich Roughing Lathe-42WN. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 333519)
LAS VEGAS, NV—2026-06-30
STV MOTORSPORTS LLC
BRIGHTON, MI—2026-03-30
NOVI PRECISION PRODUCTS, INC
ROYALTON, MN—2026-03-09
110842 - INFINITY METAL FABRICATING INC
PITTSBURGH, PA—2026-02-12
F TINKER & SONS CO
CHALFONT, PA—2026-01-14
ROLL FORMER CORPORATION
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347156531.