Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ROSS & ASSOCIATES OF RIVER FALLS, WISCONSIN LIMITED

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ROSS & ASSOCIATES OF RIVER FALLS, WISCONSIN LIMITED in 224 W 5TH AVE., MINONG, WI 54859 (NAICS 236210). OSHA activity number 347159758.

Watch Ross & Associates OF River Falls, Wisconsin Limited — free Get an email when a new federal OSHA severe-injury report for Ross & Associates OF River Falls, Wisconsin Limited is published. One employer, no account, unsubscribe in one click.
Site address
224 W 5TH AVE.
City
MINONG
State
WI
ZIP
54859
Mailing
246 SUMMIT STREET, RIVER FALLS, WI 54022
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236210
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.404 B01 III C

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $2350.00 · Current $1645.00 Reduced
29 CFR 1926.404(b)(1)(iii)(C): Where an assured equipment grounding conductor program was being utilized, the employer did not ensure that each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, were visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage:  (a) Vehicle storage area; The protective plastic at the female plug-end of a 12 AWG flexible extension cord, connected to a corded circular saw, was broken with a piece of the plastic missing, exposing energized inner conductors.
Recent events (2)
  • — I (S) $1645
  • — Z (S) $2350

1926.405 G02 IV

Serious Gravity 1 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:  (a) Vehicle storage area, precast room; The outer insulating jacket of a 12 AWG flexible extension cord, connected to a portable heater, was damaged and open at the base of the strain relief boot, exposing inner wires and rendering the strain relief ineffective as pull was transmitted to the terminal screws.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1153 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2350.00 · Current $1645.00 Reduced

Hazardous substances 9000

29 CFR 1926.1153(c)(1): For each employee engaged in a task identified on Table 1, the employer did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, unless the employer assesses and limits the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section:  (a) Precast room; An employee was using a Dewalt brand model DCH133 Brushless Hammer Drill to drill holes into the ceiling without the use of engineering controls to reduce dust emissions as required by Table-1, paragraph (c)(1) of this section.
Recent events (2)
  • — I (S) $1645
  • — Z (S) $2350

1926.1153 D02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 9000

29 CFR 1926.1153(d)(2)(i): The employer did not assess the exposure of each employee who was or may reasonably be expected to be exposed to respirable crystalline silica at or above the action level in accordance with either the performance option in paragraph (d)(2)(ii) or the scheduled monitoring option in paragraph (d)(2)(iii) of this section:  (a) Precast room; The employer did not conduct an assessment of respirable crystalline silica exposure for an employee who was using a Dewalt brand model DCH133 Brushless Hammer Drill to drill holes into the ceiling without the use of engineering controls to reduce dust emissions as required by Table-1, paragraph (c)(1) of this section.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View ROSS & ASSOCIATES OF RIVER FALLS, WISCONSIN LIMITED's full OSHA safety record →