EL PASO, TX —
OSHA Inspection: MATTRESS LIQUIDATORS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MATTRESS LIQUIDATORS in 8201 LOCKHEED DRIVE, EL PASO, TX 79925 (NAICS 442110). OSHA activity number 347172090.
Where did this inspection happen?
- Establishment
- MATTRESS LIQUIDATORS
- Site address
- 8201 LOCKHEED DRIVE
- City
- EL PASO
- State
- TX
- ZIP
- 79925
- Mailing
- 8201 LOCKHEED DRIVE, EL PASO, TX 79925
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 442110
- Employees
- 9
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.22 C
- Issued
- Abate by
- Penalty
- Initial $4978.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.22(c): The employer did not provide, and ensure each employee used, a safe means of access and egress to and from walking-working surfaces: Warehouse: On or about December 19, 2023, employees were exposed to fall hazards in excess of 4 feet due to the employer's failure to ensure employee's use of safe access and egress to and from walking-working surfaces.
Recent events (2)
- — I (S) $3000
- — Z (S) $4978
1910.28 B12 I
- Issued
- Abate by
- Penalty
- Initial $5807.00 · Current $4000.00 Reduced
General-duty citation text
29 CFR 1910.28(b)(12)(i): Each employee on a scaffold was not protected from falling in accordance 29 CFR part 1926, subpart L: Warehouse: On or about December 19, 2023, employees were exposed to fall hazards in excess of four feet while using a Yale MSW030 Pallet Stacker as a man lift to retrieve materials from the pallet racking.
Recent events (2)
- — I (S) $4000
- — Z (S) $5807
1910.37 A03
- Issued
- Abate by
- Penalty
- Initial $3318.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: Warehouse: On or about December 19, 2023, employees were exposed to fire hazards due to a blocked fire exit.
Recent events (2)
- — I (S) $2000
- — Z (S) $3318
1910.157 D02
- Issued
- Abate by
- Penalty
- Initial $4978.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.157(d)(2):29 CFR 1910.157(d)(2): Portable fire extinguishers for use on Class A fires were not distributed so that the travel distance for employees to any extinguisher is 75 feet or less: Warehouse: On or about December 19, 2023, employees were exposed to fire hazards due to the lack of a fire extinguisher every 75 feet, or less, of travel distance.
Recent events (2)
- — I (S) $3000
- — Z (S) $4978
1910.176 B
- Issued
- Abate by
- Penalty
- Initial $4978.00 · Current $3000.00 Reduced
General-duty citation text
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse: Warehouse: On or about December 19, 2023, employees were exposed to struck by hazards due to material not stacked, blocked, interlocked or limited in height so that it was stable and secure against sliding and collapse.
Recent events (2)
- — I (S) $3000
- — Z (S) $4978
1910.305 B02 I
- Issued
- Abate by
- Penalty
- Initial $4149.00 · Current $2600.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: Warehouse: On or about December 19, 2023, employees were exposed to electrical shock hazards due to a missing light switch cover.
Recent events (2)
- — I (S) $2600
- — Z (S) $4149
1910.303 G01
- Issued
- Abate by
- Penalty
- Initial $466.00 · Current $400.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: Warehouse: On or about December 19, 2023, employees were exposed to electrical shock hazards due to inadequate access space in front of a 240V electrical panel.
Recent events (2)
- — I (O) $400
- — Z (O) $466
More inspections in this industry (NAICS 442110)
SHELBY TOWNSHIP, MI—2026-07-08
ASHLEY STORE 080
OLYMPIA, WA—2026-07-07
WA317991953 - WILLIAM H OLSON INC
CAROLINA, PR—2026-05-13
SARTON PUERTO RICO LLC
PONCE, PR—2026-05-04
SARTON PUERTO RICO LLC
PORTLAND, OR—2026-05-04
317743779 - IKEA RETAIL LLC
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source