WACO, TX —
OSHA Inspection: WACO TEJAS, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WACO TEJAS, LLC in 301 PLEASANT STREET, WACO, TX 76704 (NAICS 493110). OSHA activity number 347186405.
Where did this inspection happen?
- Establishment
- WACO TEJAS, LLC
- Site address
- 301 PLEASANT STREET
- City
- WACO
- State
- TX
- ZIP
- 76704
- Mailing
- PO BOX 1339, WACO, TX 76703
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 14
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.37 A03
- Issued
- Abate by
- Penalty
- Initial $3687.00 · Current $2212.00 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed. On December 20, 2023, and at times prior thereto, in the 1-5 warehouse, three exit routes were obstructed exposing employees to entrapment and fire hazards.
Recent events (2)
- — I (S) $2212.2
- — Z (S) $3687
1910.133 A01
- Issued
- Abate by
- Penalty
- Initial $3687.00 · Current $2212.00 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. On or about December 20, 2023, and at times prior thereto, employees working with propane tanks without eye protection were exposed to eye and face injuries: a) removing and installing the portable propane tanks from power industrial trucks, and b) refilling portable propane tanks at the main above ground storage tank.
Recent events (2)
- — I (S) $2212.2
- — Z (S) $3687
1910.138 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes. On or about December 20, 2023, and at times prior thereto, employees working with propane tanks without hand protection were exposed to chemical hazards: a) removing and installing the portable propane tanks from power industrial trucks, and b) refilling portable propane tanks at the main above ground storage tank.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 E
- Issued
- Abate by
- Penalty
- Initial $3687.00 · Current $2212.00 Reduced
General-duty citation text
29 CFR 1910.303(e): Markings were not provided on electrical equipment giving voltage, current, wattage, and other ratings as necessary. On December 20, 2023, and times prior thereto, electrical panel boxes did not have voltage ratings on the outside of the panel boxes where employees open and access the panels exposing employees to electrical hazards.
Recent events (2)
- — I (S) $2212.2
- — Z (S) $3687
1910.36 G02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points. On December 20, 2023, and at times prior thereto, in areas where employees frequently worked and too breaks exit routes were reduced to a maximum width of approximately twenty four (24") inches exposing the employees to limited egress routes in the event of an emergency.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment. On or about December 20, 2023, and at times prior thereto, 240v circuit breaker panels were obstructed preventing safe access in the event of an emergency creating struck-by, caught-in and electric shock hazards in the 6-10 building.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 493110)
PORTSMOUTH, VA—2026-07-15
DACS INC
WEST CHESTER, OH—2026-07-14
CRESCENT PARK CORPORATION
WEYMOUTH, MA—2026-07-14
SPEEDX
DUNDALK, MD—2026-07-09
WILLIAMS SCOTSMAN, INC.
ROCK HILL, SC—2026-07-08
77566 - WEST MARINE INC
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347186405.