Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WACO TEJAS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WACO TEJAS, LLC in 301 PLEASANT STREET, WACO, TX 76704 (NAICS 493110). OSHA activity number 347186405.

Watch Waco Tejas, LLC — free Get an email when a new federal OSHA severe-injury report for Waco Tejas, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
WACO TEJAS, LLC
Site address
301 PLEASANT STREET
City
WACO
State
TX
ZIP
76704
Mailing
PO BOX 1339, WACO, TX 76703
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
14
Ownership type
A

6 citations on file for this inspection.

1910.37 A03

Serious Gravity 5 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $3687.00 · Current $2212.00 Reduced
29 CFR  1910.37(a)(3): Exit route(s) were not kept free and unobstructed.  On December 20, 2023, and at times prior thereto, in the 1-5 warehouse, three exit routes were obstructed exposing employees to entrapment and fire hazards.
Recent events (2)
  • — I (S) $2212.2
  • — Z (S) $3687

1910.133 A01

Serious Gravity 5 1 instance 12 exposed
Issued
Abate by
Penalty
Initial $3687.00 · Current $2212.00 Reduced
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation.  On or about December 20, 2023, and at times prior thereto, employees working with propane tanks without eye protection were exposed to eye and face injuries:  a) removing and installing the portable propane tanks from power industrial trucks, and  b) refilling portable propane tanks at the main above ground storage tank.
Recent events (2)
  • — I (S) $2212.2
  • — Z (S) $3687

1910.138 A

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes.  On or about December 20, 2023, and at times prior thereto, employees working with propane tanks without hand protection were exposed to chemical hazards:  a) removing and installing the portable propane tanks from power industrial trucks, and  b) refilling portable propane tanks at the main above ground storage tank.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 E

Serious Gravity 5 2 instances 12 exposed
Issued
Abate by
Penalty
Initial $3687.00 · Current $2212.00 Reduced
29 CFR  1910.303(e): Markings were not provided on electrical equipment giving voltage, current, wattage, and other ratings as necessary.  On December 20, 2023, and times prior thereto, electrical panel boxes did not have voltage ratings on the outside of the panel boxes where employees open and access the panels exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $2212.2
  • — Z (S) $3687

1910.36 G02

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.36(g)(2): Exit access(es) were not at least 28 inches (71.1 cm) wide at all points.  On December 20, 2023, and at times prior thereto, in areas where employees frequently worked and too breaks exit routes were reduced to a maximum width of approximately twenty four (24") inches exposing the employees to limited egress routes in the event of an emergency.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment.  On or about December 20, 2023, and at times prior thereto, 240v circuit breaker panels were obstructed preventing safe access in the event of an emergency creating struck-by, caught-in and electric shock hazards in the 6-10 building.