CALDWELL, ID —
OSHA Inspection: LOST RIVER FABRICATION LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LOST RIVER FABRICATION LLC in 21955 MIDDLETON ROAD, CALDWELL, ID 83605 (NAICS 332312). OSHA activity number 347188443.
Where did this inspection happen?
- Establishment
- LOST RIVER FABRICATION LLC
- Site address
- 21955 MIDDLETON ROAD
- City
- CALDWELL
- State
- ID
- ZIP
- 83605
- Mailing
- 21955 MIDDLETON ROAD, CALDWELL, ID 83605
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 9
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $2074.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces were kept in a clean, orderly, and sanitary condition. a) On or about December 20, 2023, and times prior thereto, the walking path near and around the entrance/exit of the facility was obstructed by welding equipment, and palleted material. NOTE: Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $2074
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $2765.00 · Current $1383.00 Reduced
General-duty citation text
29 CFR 1910.151(c):Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use a) On or about December 20, 2023 and times prior thereto, employees refilled electrolyte fluid in forklift batteries. NOTE: Abatement certification is required for this item.
Recent events (2)
- — I (S) $1382.5
- — Z (S) $2765
1910.178 L02 II
- Issued
- Abate by
- Penalty
- Initial $4839.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(2)(ii): The employer did not ensure that each operator had successfully completed the training consisting of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. a) On or about December 20, 2023, and times prior thereto, employees operated forklifts to move material and products around the site and were not provided with formal instruction. NOTE: Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (S) $4839
1910.243 C01
- Issued
- Abate by
- Penalty
- Initial $4148.00 · Current $2074.00 Reduced
General-duty citation text
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4)" a) On or about December 20, 2023 and times prior thereto, employees used a Hercules Serial#: 36871-2151 portable grinder. b) On or about December 20, 2023 and times prior thereto, employees used a Bosch Serial#: GWX13-50VSP portable grinder. c) On or about December 20, 2023 and times prior thereto, employees used a DeWalt 20v Max - No Serial# portable grinder. NOTE: Abatement certification is required for this item.
Recent events (2)
- — I (S) $2074
- — Z (S) $4148
1910.253 B02 II
- Issued
- Abate by
- Penalty
- Initial $3457.00 · Current $1728.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders were not located away from elevators, stairs, and gangways, or where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. a) On or about December 20, 2023, and times prior thereto, cylinders were strapped to a metal storage shelf located where they could be damaged by passing forklift traffic, objects falling from the shelf, or subject to tampering by unauthorized persons. NOTE: Abatement certification is required for this item.
Recent events (2)
- — I (S) $1728
- — Z (S) $3457
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A):Flexible cords and cables were used as a substitute for fixed wiring of a structure. a) On or about December 20, 2023 and times prior thereto, an extension cord was used to power a permanent security system. NOTE: Abatement certification is required for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at LOST RIVER FABRICATION LLC
CALDWELL, ID—2023-12-20 00:00:00
LOST RIVER FABRICATION LLC
View LOST RIVER FABRICATION LLC's full OSHA safety record →
More inspections in this industry (NAICS 332312)
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
CAMDEN, NJ—2026-07-08
CENTRAL METALS, INC.
SACRAMENTO, CA—2026-07-07
MARTIN'S STEEL WORKS, INC
LOUISVILLE, KY—2026-07-01
69275 - NORTH AMERICAN INDUSTRIAL SUPPLY INC
More inspections in ID
GOODING, ID—2026-07-10
DAHLGREN INDUSTRIAL INC.
MERIDIAN, ID—2026-07-10
IDAHO HOMES CONSTRUCTION LLC
MERIDIAN, ID—2026-07-10
DIAMOND CONCRETE, LLC
BOISE, ID—2026-07-09
POWERHOUSE ELECTRIC INC.
BOISE, ID—2026-07-09
MARK GUHO CONSTRUCTION COMPANY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347188443.