Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CHIPPEWA VALLEY WAREHOUSE OPERATIONS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CHIPPEWA VALLEY WAREHOUSE OPERATIONS, INC. in 5613 3M DRIVE, MENOMONIE, WI 54751 (NAICS 493110). OSHA activity number 347200198.

Watch Chippewa Valley Warehouse Operations, INC. — free Get an email when a new federal OSHA severe-injury report for Chippewa Valley Warehouse Operations, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5613 3M DRIVE
City
MENOMONIE
State
WI
ZIP
54751
Mailing
5613 3M DRIVE, MENOMONIE, WI 54751
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
15
Ownership type
A

7 citations on file for this inspection.

1910.37 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3134.00 · Current $2194.00 Reduced
29 CFR 1910.37(b)(1): Each exit route was not adequately lighted so that employees with normal vision could see along the exit route:  (a) North building (Freitag Dr.) - southwest corner; An emergency exit route was not adequately lighted along the route.
Recent events (2)
  • — I (S) $2193.8
  • — Z (S) $3134

1910.37 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  (a) North building (Freitag Dr.) - northeastern side; An emergency exit door was not identified with signage indicating its location.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:  (a)  North building (Freitag Dr.) - southwest corner; Signage indicating the direction of travel to the nearest emergency exit was not posted.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L04 III

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2350.00 · Current $1645.00 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  (a) Throughout both facilities; Various forklift operators had not had their performance re-evaluated at least once every three years.
Recent events (2)
  • — I (S) $1645
  • — Z (S) $2350

1910.178 N04

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(n)(4): Industrial truck driver(s) were not required to slow down and sound the horn at cross aisles and wherever vision was obstructed  (a) South building (3M Dr.) - throughout facility; Forklift operators were observed exiting and crossing aisles where vision was obstructed without utilizing horns to announce their presence to other vehicle and foot traffic.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C01

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  (a) Throughout both facilities; Multiple fire extinguishers were not identified with a sign/placard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  (a) South building (3M Dr.) - southcentral section; A CAT forklift and battery charger were located directly in front of an electrical panel, reducing the work area to approximately nine inches.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

SPEEDX