2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: EXXONMOBIL CHEMICAL COMPANY-BEAUMONT POLYETHYLENE PLANT

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of EXXONMOBIL CHEMICAL COMPANY-BEAUMONT POLYETHYLENE PLANT in 11440 HIGHWAY 90, BEAUMONT, TX 77713 (NAICS 325211). OSHA activity number 347214314.

Watch Exxonmobil Chemical Company-Beaumont Polyethylene Plant — free Get an email when a new federal OSHA severe-injury report for Exxonmobil Chemical Company-Beaumont Polyethylene Plant is published. One employer, no account, unsubscribe in one click.
Site address
11440 HIGHWAY 90
City
BEAUMONT
State
TX
ZIP
77713
Mailing
P.O. BOX 2295, BEAUMONT, TX 77704
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
Employees
220
Ownership type
A

3 citations on file for this inspection.

1910.147 D02

Other-than-serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $11524.00 · Current $11524.00
29 CFR 1910.147(d)(2):  An orderly shutdown was not utilized to avoid any additional or increased hazard(s) to employees as a result of equipment stoppage:  a)  On or about January 11, 2024, in the IC4 unloading area, the shutdown was not orderly.
Recent events (2)
  • — I (O) $11524
  • — Z (S) $11524

1910.147 C04 II

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $11524.00 · Current $0.00 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to the items of this section:   (a) On or about January 11, 2024, in the IC4 unloading area, where employees were preparing for an inlet strainer replacement without a specific procedure for controlling the unexpected release of chemical energy while clearing the residual ethylene from the line.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11524

1910.147 D05 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(d)(5)(i):  All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices:  (a) On or about January 11, 2024, in the IC4 unloading area, where residual ethylene was not relieved and rendered safe after the application of lockout or tagout devices to energy isolating devices.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347214314.