Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JARIK ROOFING

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of JARIK ROOFING in BLOCK 24 HAWTHORNE DRIVE, HARRISBURG, PA 17110 (NAICS 238160). OSHA activity number 347228819.

Watch Jarik Roofing — free Get an email when a new federal OSHA severe-injury report for Jarik Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
JARIK ROOFING
Site address
BLOCK 24 HAWTHORNE DRIVE
City
HARRISBURG
State
PA
ZIP
17110
Mailing
1094 GREENWALL PL APT TA, FREDERICK, MD 21703
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.502 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4148.00 · Current $4148.00
29 CFR  1926.502(d)(1): Personal fall arrest system connectors were not drop forged, pressed or formed steel, or made of equivalent materials:   (a)  Block 24 Hawthorne Drive, Harrisburg PA - On or about January 23, 2024, an employee conducted roofing activities approximately 12 feet above grade on a roof with a slope of 6-12.   The employee used a personal fall arrest system with a positioning device that were not constructed of drop forged steel, exposing the employee to a fall hazard.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $4148

1926.502 D21

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.502(d)(21):Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service:  (a) Block 24 Hawthorne Drive, Harrisburg PA - On or about January 23, 2024, an employee conducted roofing activities approximately 12 feet above grade on a roof with a slope of 6-12.  An employee to use a personal fall arrest system that had worn or damaged nylon webbing and also corrosion damage on the dee ring and buckles.   (b)  Block 24 Hawthorne Drive, Harrisburg PA -On or about January 23, 2024, an employee conducted roofing activities approximately 12 feet above grade on a roof with a slope of 6-12.  An employee to use a personal fall arrest system with a 4-foot shock absorbing lanyard which was shortened using duct tape.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1926.503 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:  (a) Block 24 Hawthorne Drive, Harrisburg PA -On or about January 23, 2024, an employee conducted roofing activities approximately 12 feet above grade on a roof with a slope of 6-12.  The employer did not provide adequate fall protection training to ensure employee recognized hazards and the procedures to minimize the hazards.   Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3457.00 · Current $3457.00
29 CFR  1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  (a) Block 24 Hawthorne Drive, Harrisburg PA - On or about January 23, 2024, the Werner 20-foot aluminum extension ladder was not positioned to provide at least 3 feet of side rail above the roof edge which exposed employees to a fall hazard of approximately 12 feet to grade.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $3457

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347228819.