Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JP MASONRY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JP MASONRY in 31505 LA-1, WHITE CASTLE, LA 70788 (NAICS 238140). OSHA activity number 347251530.

Watch JP Masonry — free Get an email when a new federal OSHA severe-injury report for JP Masonry is published. One employer, no account, unsubscribe in one click.
Establishment
JP MASONRY
Site address
31505 LA-1
City
WHITE CASTLE
State
LA
ZIP
70788
Mailing
200 MAUD OLIVE DR, BELLE CHASSE, LA 70037
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
8
Ownership type
A

3 citations on file for this inspection.

1926.451 B01 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $3687.00 · Current $0.00 Reduced
29 CFR  1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary.  On or about January 31, 2024, employees performed masonry tasks where the spacing between the planks of the scaffold was greater than one inch.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3687

1926.451 B02

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide. On or about January 31, 2024, employees performed masonry tasks on a scaffold where the walkways were less than the required 18 inches.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 E01

Deleted Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffolds, structure, personnel hoist, or similar surface was not used.  Cross braces were used as a means of access.  On or about January 31, 2024, employees performed masonry tasks on a scaffold where the platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, or a means of egress or entry were not available. Employees had to use the Cross braces as a means of accessing and egressing the scaffold.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View JP MASONRY's full OSHA safety record →