NORTHBRIDGE, MA —
OSHA Inspection: POLYFOAM, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of POLYFOAM, LLC in 2355 PROVIDENCE ROAD, NORTHBRIDGE, MA 01534 (NAICS 326140). OSHA activity number 347271090.
Where did this inspection happen?
- Establishment
- POLYFOAM, LLC
- Site address
- 2355 PROVIDENCE ROAD
- City
- NORTHBRIDGE
- State
- MA
- ZIP
- 01534
- Mailing
- 2355 PROVIDENCE ROAD POB 906, NORTHBRIDGE, MA 01534
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326140
- Employees
- 120
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 I
- Issued
- Abate by
- Penalty
- Initial $14518.00 · Current $13670.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: 2355 Providence Road, Northbridge, MA: On and before February 9, 2024, employees performed maintenance and servicing activities on Molding Press #9 without a documented energy control procedure to direct the control of potentially hazardous energy.
Recent events (2)
- — I (S) $13670
- — Z (S) $14518
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: 2355 Providence Road, Northbridge, MA: On and before February 9, 2024, the employer had not performed a comprehensive periodic inspection of energy control procedures for all multi-energy sources machines, including the Molding Press #9 machine, at least annually to verify that each procedure was adequate and being properly used by employees. *Abatement Notes: A periodic inspection shall include the following elements: - Appointment of an authorized employee to inspect each unique procedure for deviations and inadequacies during an energy control task - A review by inspector with each authorized employee, of that employee's responsibilities under each energy control procedure they are authorized to use - Certification that the periodic inspections had been performed by identifying the machines or equipment on which the energy control procedures were being utilized, the dates of the inspections, the employees included in the inspections, and the persons performing the inspections *Abatement notes are intended only to provide clarity regarding existing requirements under the law or agency policies. Abatement notes do not create (or diminish) legal obligations under the Occupational Safety and Health Act.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 A05
- Issued
- Abate by
- Penalty
- Initial $8296.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1910.178(a)(5):The powered industrial truck was equipped with front-end attachments other than factory installed attachments, however the employer did not request that the truck be marked to identify the attachments and show the approximate weight of the truck and attachment combination at maximum elevation with load laterally centered: 2355 Providence Road, Northbridge, MA: On and before February 9, 2024, employees operated powered industrial trucks with a boom attachment that was not included on the data plates to identify approximate weight of the truck and capacity at maximum elevation with load laterally centered.
Recent events (2)
- — I (O) $0
- — Z (S) $8296
1910.178 Q07
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.178(q)(7): Powered industrial truck(s) which were used on a round-the-clock basis were not examined for defects after each shift: 2355 Providence Road, Northbridge, MA: On and before February 9, 2024, some powered industrial trucks were being used during multiple shifts and were only being inspected once per day.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 326140)
BOLINGBROOK, IL—2026-06-09
CLARK FOAM PRODUCTS CORPORATION
SWEDESBORO, NJ—2026-04-30
DIVERSIFIED FOAM PRODUCTS
VISALIA, CA—2026-04-14
PREGIS INNOVATIVE PACKAGING LLC
CORONA, CA—2026-03-27
DART CONTAINER CORPORATION
EDISON, NJ—2026-03-26
CRYOPAK, INC.
More inspections in MA
WORCESTER, MA—2026-07-10
QUINSIGAMOND COMMUNITY COLLEGE
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
EVERETT, MA—2026-07-10
HORIZON RETAIL CONSTRUCTION INC
NORTON, MA—2026-07-09
DYNAMIC RESIDENTIAL ROOF MARKETING, LLC
NORTON, MA—2026-07-09
LM GENERAL CONSTRUCTION INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347271090.