OSHA Inspection: DYNAMIC RENEWABLES, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DYNAMIC RENEWABLES, INC. in 19051 US-81, LAKE NORDEN, SD 57248 (NAICS 221117). OSHA activity number 347287138.

Watch Dynamic Renewables, INC. — free Get an email when a new federal OSHA severe-injury report for Dynamic Renewables, INC. is published. One employer, no account, unsubscribe in one click.
Site address
19051 US-81
City
LAKE NORDEN
State
SD
ZIP
57248
Mailing
150 MAIN STREET SUITE 102, MENASHA, WI 54952
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221117
Employees
56
Ownership type
A

2 citations on file for this inspection.

1910.119 F01

Other-than-serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4839.00 · Current $4839.00
29 CFR  1910.119(f)(1):The employer did not develop and implement written operating procedures that provided clear instructions for safely conducting activities involved in each covered process:  (a)Dynamic Renewables, Inc at 19051 US-81, Lake Norden, SD 57248: On or about and at times prior to February 15, 2024, the employer did not ensure that valves, fans, pumps and other equipment listed on the  operational steps of the Upgrade Operations OP-502 Revision 0 were clearly identified to ensure employees performed operational steps utilizing the correct equipment. Examples include but are not limited to:  -Section 5.2.3: Ensure open manual gas inflow and gas outflow valves (Page 4 of 16). -Section 5.3.12: At the HMI, set both fan and valve to auto (Page 5 of 16).  -Section 10.2.20: Close manual valve directly downstream of the recirculatory pump (Page 14 of 16).  -Section 10.2.22: Open the valve behind the pump slowly (Page 14 of 16).  -Section 10.2.25: Check, open and manually adjust the hand valve in the control loop for redox, pH and temperature measurements (Page 14 of 16).  -Section 10.2.44: Open the ball valve between the bioreactor and sulfur settler (Page 15 of 16).    Inadvertent operation of equipment or failure to isolate key equipment can cause or contribute to a release of a highly hazardous chemical, exposing employees to physical and chemicals hazards associated with raw biogas and other process chemicals.
Recent events (2)
  • — I (O) $4839
  • — Z (S) $4839

1910.119 G03

Other-than-serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.119(g)(3): Training documentation. The employer did not ascertain that each employee involved in operating a process had received and understood the training required by this paragraph. The employer did not prepare a record which contained the identity of the employee, the date of training, and the means used to verify that the employee understood the training:  (a)Dynamic Renewables, Inc at 19051 US-81, Lake Norden, SD 57248: On or about and at times prior to February 15, 2024 the employer did not ensure documentation of employee training included the means used to verify that the employee understood the training.