TWIN LAKES, WI —
OSHA Inspection: ALLIED PLASTICS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ALLIED PLASTICS, INC. in 150 HOLY HILL ROAD, TWIN LAKES, WI 53181 (NAICS 326199). OSHA activity number 347292476.
Where did this inspection happen?
- Establishment
- ALLIED PLASTICS, INC.
- Site address
- 150 HOLY HILL ROAD
- City
- TWIN LAKES
- State
- WI
- ZIP
- 53181
- Mailing
- 150 HOLY HILL ROAD, TWIN LAKES, WI 53181
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 348
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C02 II
- Issued
- Abate by
- Penalty
- Initial $13711.00 · Current $9598.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(2)(ii): The employer's tagout energy control program procedures did not successfully comply with 29 CFR 1910.147(c)(3) and no lockout was provided for employee protection. (a) On or about February 21, 2024, located at 150 Holy Hill Road, Twin Lakes, WI 53181, the employer did not ensure that the use of tagout energy control program complied with 1910.147(c)(3) in that tags were not required to be affixed to the same location as locks and that all energy sources were rendered isolated and safe prior to entry into the MAAC #1 Thermoform machine, exposing employees to thermal energy hazards with temperatures of approximately 200 degrees Fahrenheit. (b) On or about February 27, 2024, located at 150 Holy Hill Road, Twin Lakes, WI 53181, the employer did not ensure that the use of tagout energy control program complied with 1910.147(c)(3) in that tags were not required to be affixed to the same location as locks and that energy sources were rendered isolated and safe prior to entry into the MAAC #10 Thermoform machine, exposing employees to struck-by hazards.
Recent events (2)
- — I (O) $9597.7
- — Z (S) $13711
1910.147 C05 II C 2
- Issued
- Abate by
- Penalty
- Initial $5876.00 · Current $4113.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(5)(ii)(C)(2): Tagout devices and their means of attachment were not substantial enough to prevent inadvertent or accidental removal. (a) On or about February 27, 2024, located at 150 Holy Hill Road, Twin Lakes, WI 53181, the employer did not supply employees with a means of attaching tagout devices that were non-reusable, self-locking, and non-releasable with a minimum unlocking strength of no less than 50 pounds to prevent inadvertent or accidental removal, while performing set-up operations on the MAAC #10 Thermoform Machine.
Recent events (2)
- — I (O) $4113.2
- — Z (S) $5876
1910.147 C06 I
- Issued
- Penalty
- Initial $9795.00 · Current $6857.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed. (a) On or about February 21, 2024, located at 150 Holy Hill Road, Twin Lakes, WI 53181, the employer did not evaluate the company's hazardous energy control program annually to ensure machine specific energy control procedures were current, and that authorized employees were correctly implementing energy control procedures when performing services and maintenance on the MAAC#1 and MAAC #10 Thermoform Equipment.
Recent events (2)
- — I (O) $6856.5
- — Z (S) $9795
1910.147 C06 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: (a) On or about February 21, 2024, located at 150 Holy Hill Road, Twin Lakes, WI 53181, the employer failed to certify, in accordance with this subpart, that periodic inspection of their hazardous energy control procedures had been performed.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.147 D
- Issued
- Abate by
- Penalty
- Initial $13711.00 · Current $9598.00 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6). (a) On or about February 16, 2024, located at 150 Holy Hill Road, Twin Lakes, WI 53181, the employer did not ensure the employee implemented energy control procedures prior to entering the point of operation of the MAAC#1 Thermoform machine to perform troubleshooting with the clamps used to secure the mold. The machine was not isolated from all energy sources prior to engaging in these troubleshooting activities, exposing employees to severe burns from the thermal energy source. (b) On or about February 27, 2024, located at 150 Holy Hill Road, Twin Lakes, WI 53181, the employer did not ensure employees implemented energy control procedures prior to entering the point of operation of the MAAC#10 Thermoform machine to perform set-up operations consisting of but not limited to: mold changing was conducted. The machine was not isolated from all energy sources prior to engaging in these set-up servicing, exposing employees to mechanical energy hazards.
Recent events (2)
- — I (O) $9597.7
- — Z (S) $13711
More inspections at ALLIED PLASTICS, INC.
TWIN LAKES, WI—2016-08-11 00:00:00
ALLIED PLASTICS, INC.
TWIN LAKES, WI—2013-02-14 00:00:00
ALLIED PLASTICS, INC.
BROOKLYN PARK, MN—1986-01-16
ALLIED PLASTICS, INC.
Gastonia, NC—1983-12-06
ALLIED PLASTICS INC
Doraville, GA—1976-12-08
ALLIED PLASTICS INC
View ALLIED PLASTICS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326199)
CONNEAUT, OH—2026-07-13
CONTINENTAL STRUCTURAL PLASTICS
PETALUMA, CA—2026-07-10
LABCON NORTH AMERICA
KEEWATIN, MN—2026-07-09
111565 - TACKLE TAMER PRODUCTS INC
EAST FLAT ROCK, NC—2026-07-09
161517 - ELKAMET, INC.
LANESBOROUGH, MA—2026-07-08
LANSEN MOLD CO., INC.
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347292476.