Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: GULF COAST PRECAST, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of GULF COAST PRECAST, INC. in 5410 DOUBLE EAGLE CIRCLE BUILDING 2200, AVE MARIA, FL 34142 (NAICS 238120). OSHA activity number 347301640.

Watch Gulf Coast Precast, INC. — free Get an email when a new federal OSHA severe-injury report for Gulf Coast Precast, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5410 DOUBLE EAGLE CIRCLE BUILDING 2200
City
AVE MARIA
State
FL
ZIP
34142
Mailing
2506 PRECAST CT, FORT MYERS, FL 33916
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
7
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $6452.00 · Current $3871.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):  On or about 2/6/2024, at Building 2200, 5410 Double Eagle Circle, Ave Maria, Florida, two employees were exposed to 9-foot fall hazard while working on the first floor of a multi-family residential building that was under construction and were within 3 feet of an open sided edge without conventional fall protection.
Recent events (2)
  • — I (S) $3871.2
  • — Z (S) $6452

1926.701 B

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $4702.00 · Current $2821.00 Reduced
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall, was not guarded to eliminate the hazard of impalement:   On or about 2/6/2024, at Building 2200, 5410 Double Eagle Circle, Ave Maria, Florida, two employees were exposed to an impalement hazard while working in close proximity of uncapped rebars on the first floor of a multi-family residential building.
Recent events (2)
  • — I (S) $2821.2
  • — Z (S) $4702

1926.1431 A

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $3918.00 · Current $2351.00 Reduced
29 CFR  1926.1431(a): The use of equipment to hoist employees is prohibited except where the employer demonstrates that the erection, use, and dismantling of conventional means of reaching the work area, such as a personnel hoist, ladder, stairway, aerial lift, elevating work platform, or scaffold, would be more hazardous, or is not possible because of the project's structural design or worksite conditions. This paragraph does not apply to work covered by subpart R (Steel Erection) of this part.   On or about 2/6/2024 and at times prior, at Building 2200, 5410 Double Eagle Circle, Ave Maria, Florida, an employee was exposed to a 9-foot fall hazard while standing on a precast concrete form being hoisted into position with a crane.
Recent events (2)
  • — I (S) $2350.8
  • — Z (S) $3918

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347301640.