BROOKLYN, NY —
OSHA Inspection: ZITO ROOFING INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ZITO ROOFING INC. in 1469 W 8TH STREET, BROOKLYN, NY 11204 (NAICS 238160). OSHA activity number 347304669.
Where did this inspection happen?
- Establishment
- ZITO ROOFING INC.
- Site address
- 1469 W 8TH STREET
- City
- BROOKLYN
- State
- NY
- ZIP
- 11204
- Mailing
- 2140 E 74TH STREET, BROOKLYN, NY 11234
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $4839.00 · Current $3200.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1):When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. Location: Worksite; roof. a) On 02/26/2024, employees utilizing an extension ladder to access a rooftop, did not ensure its side rails were extended at least 3 feet above the upper landing surface.
Recent events (2)
- — I (S) $3200
- — Z (S) $4839
1926.501 B10
- Issued
- Abate by
- Penalty
- Initial $32265.00 · Current $22700.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system. Location: Worksite; roof. a) On 02/26/2024, employees engaging in roofing repair were exposed to fall hazard of 30 feet to the sidewalk below. Employees were not wearing a harness nor utilizing any fall protection.
Recent events (2)
- — I (W) $22700
- — Z (W) $32265
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347304669.