CANON CITY, CO —
OSHA Inspection: DFC CERAMICS LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of DFC CERAMICS LLC in 515 SOUTH 9TH STREET, CANON CITY, CO 81212 (NAICS 327110). OSHA activity number 347309585.
Where did this inspection happen?
- Establishment
- DFC CERAMICS LLC
- Site address
- 515 SOUTH 9TH STREET
- City
- CANON CITY
- State
- CO
- ZIP
- 81212
- Mailing
- 515 SOUTH 9TH STREET, CANON CITY, CO 81212
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327110
- Employees
- 30
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.1053 D03 III
- Issued
- Abate by
- Penalty
- Initial $6857.00 · Current $3428.00 Reduced
9000
General-duty citation text
29 CFR 1910.1053(d)(3)(iii):Where the most recent exposure monitoring indicated that employee exposures were at or above the action level but at or below the PEL, the employer did not repeat such monitoring within six months of the most recent monitoring: (a) On or about February 27, 2024, and at times prior, the employer did not repeat exposure monitoring when employee exposures were at or above the Action Level but below the Permissible Exposure Limit.
Recent events (2)
- — I (S) $3428
- — Z (S) $6857
1910.1053 D03 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
9000
General-duty citation text
29 CFR 1910.1053(d)(3)(iv):Where the most recent exposure monitoring indicated that employee exposures were above the PEL, the employer did not repeat such monitoring within three months of the most recent monitoring: (a) On or about February 27, 2024, and at times prior, the employer did not repeat exposure monitoring when employee exposures were at or above the Permissible Exposure Limit.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1053 F02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
9000
General-duty citation text
29 CFR 1910.1053(f)(2)(i):The employer did not establish and implement a written exposure control plan: (a) On or about February 27, 2024, and at times prior, the employer did not establish and implement a written exposure control plan when employees were exposed to respirable crystalline silica.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 327110)
COLORADO SPRINGS, CO—2026-05-14
CERAMIC PRO
BETHLEHEM, PA—2026-05-13
NATIONAL MAGNETICS GROUP, INC.
BETHLEHEM, PA—2026-05-13
NATIONAL MAGNETICS GROUP, INC.
AURORA, NY—2026-04-22
MACKENZIE - CHILDS LLC.
ARLINGTON HEIGHTS, IL—2026-04-10
THROWN ELEMENTS POTTERY LLC
More inspections in CO
BROOMFIELD, CO—2026-07-16
WAVELYNX TECHNOLOGIES LLC
COLORADO SPRINGS, CO—2026-07-15
ELMER CONTRACTOR LLC
SHERIDAN, CO—2026-07-15
JOHN'S COLLISION REPAIR, INC.
CENTENNIAL, CO—2026-07-15
BRAKES PLUS, INC
ENGLEWOOD, CO—2026-07-15
PCL CIVIL CONSTRUCTORS INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347309585.