Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: E & C PRECAST CONCRETE INC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of E & C PRECAST CONCRETE INC in 9608 NORTH MOORE ROAD, LITTLETON, CO 80125 (NAICS 423320). OSHA activity number 347311086.

Watch E & C Precast Concrete INC — free Get an email when a new federal OSHA severe-injury report for E & C Precast Concrete INC is published. One employer, no account, unsubscribe in one click.
Site address
9608 NORTH MOORE ROAD
City
LITTLETON
State
CO
ZIP
80125
Mailing
9608 NORTH MOORE ROAD, LITTLETON, CO 80125
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423320
Employees
33
Ownership type
A

7 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4113.00 · Current $2468.00 Reduced

Hazardous substances 9000

29 CFR  1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  a)  On or about February 28, 2024, and at times prior, the employer did not provide a written respiratory protection program to employees who wore half-face respirators and N-95s in the workplace. The employee grinding on concrete wore a half-face respirator with P100 filters and the employee sanding outside wore an N95 (both mandatory); there was no written respiratory protection program that included worksite-specific procedures, training required, fit testing, maintenance and storage, medical evaluations, and the other requirements required in 1910.134(C)(1) exposing employees to physiological burdens.   Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $2467.8
  • — Z (S) $4113

1910.134 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 9000

29 CFR  1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a)  On or about February 28, 2024, and at times prior, the employer did not provide a medical evaluation to employees who wore half-face respirators and N-95s in the workplace. The employee grinding on concrete wore a half-face respirator with P100 filters and the employee sanding outside wore an N95; there were no medical evaluations before usage, exposing employees to physiological burdens.   Abatement Note: Abatement certification and documentation are required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 H02 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.134(h)(2)(i):  Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or  were not packed or stored to prevent deformation of the facepiece and exhalation valve:  a)  On or about February 28, 2024, and at times prior, the employer did not ensure that half-face respirators with P100 filters were stored in a manner to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.25 B01

Other-than-serious 1 instance 4 exposed
Issued
Penalty
Initial $770.00 · Current $462.00 Reduced
29 CFR  1910.25(b)(1): 29 CFR 1910.25(b)(1): The employer did not ensure that handrails, stair rail systems, and guardrail systems are provided in accordance with � 1910.28.   a) On or about February 28, 2024, employees were exposed to fall hazards due to the lack of a stair railing on one side of the exterior stairs between the upper office and lower level buildings. The employer failed to ensure the open edge along the stairs was guarded in a way that employees would not fall at more than four feet in height. The employer did not ensure that each employee on a walking-working surface (e.g. stair rail system) with an unprotected side more than 4 feet above a lower level is protected from falling by guardrail systems.
Recent events (2)
  • — I (O) $462
  • — Z (O) $770

1910.178 L04 III

Other-than-serious 1 instance 5 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.178(l)(4)(iii):An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:  a) On or about February 28, 2024, and at times prior, employees were exposed to struck by and crush by hazards. The employer failed to ensure  Powered Industrial Truck operators were evaluated at least every three years. Employees utilize the forklifts  to move heavy concrete objects and other materials on the lot and throughout the facility.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  a) On or about February 28, 2024, and at times prior, the employer failed to ensure the area in front of the electrical panel of the welding shop was clear. Metal structures and other heavy objects were blocking access to the panel, preventing rapid emergency shut downs from occurring.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1053 D04

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00

Hazardous substances 9000

29 CFR  1910.1053(d)(4): The employer did not reassess exposures whenever a change in the production, process, control equipment, personnel, or work practices was reasonably expected to result in new or additional exposures at or above the action level, or when the employer had reason to believe that new or additional exposures at or above the action level have occurred:   a)  On or about March 22, 2024, and at times prior the employer did not conduct exposure assessments for employees who may reasonably be expected to be exposed to respirable crystalline silica at or above the action level.  The grinder and water hose were a new addition to the employees' operations.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View E & C PRECAST CONCRETE INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347311086.