Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: XTREME FX LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of XTREME FX LLC in 1500 MASTERS BLVD, CHAMPIONS GATE, FL 33896 (NAICS 713990). OSHA activity number 347315178.

Watch Xtreme FX LLC — free Get an email when a new federal OSHA severe-injury report for Xtreme FX LLC is published. One employer, no account, unsubscribe in one click.
Establishment
XTREME FX LLC
Site address
1500 MASTERS BLVD
City
CHAMPIONS GATE
State
FL
ZIP
33896
Mailing
1381 MARKET CIRCLE UNIT 4, PORT CHARLOTTE, FL 33953
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Last modified
Data loaded
NAICS code
713990
Employees
102
Ownership type
A

7 citations on file for this inspection.

1910.119 C01

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $14518.00 · Current $14518.00
29 CFR  1910.119(c)(1): The employer did not develop a written plan of action regarding the implementation of employee participation.   a.) At 1500 Masters Blvd, Champions Gate, FL: On or about February 19, 2024, employees were exposed to explosion, deflagration, and fire hazards when assembling Hazard Division 1.3G and 1.4G  explosives consisting of display fireworks and electric igniters (e-matches), in that a written program for employee participation in a PSM covered processes including, but not limited to, the "e-matching" assembly process had not been developed.
Recent events (3)
  • — R (S) $14518
  • — C (S) $14518
  • — Z (S) $14518

1910.119 D

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $14518.00 · Current $0.00 Reduced
29 CFR 1910.119(d): The employer did not complete a compilation of written process safety information, including information pertaining to the hazards of the highly hazardous chemicals used or produced by the process, information pertaining to the technology of the process, and information pertaining to the equipment in the process before conducting the process hazard analysis:   a. At 1500 Masters Blvd, Champions Gate, FL: On or about February 19, 2024, employees were exposed to explosion, deflagration, and fire hazards due to assembling Hazard Division 1.3G and 1.4G explosives consisting of display fireworks and electric igniters (e-matches), in that written process safety information had not been compiled to identify and understand the hazards of the process.
Recent events (3)
  • — R (S) $0
  • — C (S) $14518
  • — Z (S) $14518

1910.1200 G11

Other-than-serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(g)(11): Safety data sheets shall also be made readily available, upon request, to designated representatives, the Assistant Secretary, and the Director, in accordance with the requirements of � 1910.1020(e).   a.) At 1500 Masters Blvd, Champions Gate, FL: On or about February 19, 2024, employees were exposed to explosion, deflagration, and fire hazards due to assembling Hazard Division 1.3G and 1.4G explosives consisting of display fireworks and electric igniters (e-matches), in that the employer did not provide safety data sheet in a timely manner after written request for document was sent on April 22, 2024 and subpoena duces tecum was sent on May 21, 2024.
Recent events (3)
  • — R (O) $0
  • — C (S) $0
  • — Z (S) $0

1910.119 E01

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $14518.00 · Current $0.00 Reduced
29 CFR  1910.119(e)(1): The employer did not perform an initial process hazard analysis (hazard evaluation) on processes covered by 29 CFR 1910.119:  a.) At 1500 Masters Blvd, Champions Gate, FL: On or about February 19, 2024, employees were exposed to explosion, deflagration, and fire hazards due to assembling Hazard Division 1.3G and 1.4G explosives consisting of display fireworks and electric igniters (e-matches), in that an initial process hazard analysis had not been conducted.
Recent events (3)
  • — R (S) $0
  • — C (S) $14518
  • — Z (S) $14518

1910.119 F01

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $14518.00 · Current $13066.00 Reduced
29 CFR  1910.119(f)(1): The employer did not develop and implement written operating procedures that provide clear instructions for safely conducting activities involved in each covered process consistent with the process safety information:  a.) At 1500 Masters Blvd, Champions Gate, FL: On or about February 19, 2024, employees were exposed to explosion, deflagration, and fire hazards due to assembling Hazard Division 1.3G and 1.4G explosives consisting of display fireworks and electric igniters (e-matches), in that written operating procedures had not been developed to provide clear instructions for safely conducting operations including, but not limited to, the assembly process.
Recent events (3)
  • — R (S) $13066
  • — C (S) $14518
  • — Z (S) $14518

1910.119 I01

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $14518.00 · Current $0.00 Reduced
29 CFR 1910.119(i)(1): The employer did not perform a pre-startup safety review for new facilities and for modified facilities when the modification was significant enough to require a change in the process safety information.  a.) At 1500 Masters Blvd, Champions Gate, FL: On or about February 19, 2024, employees were exposed to explosion, deflagration, and fire hazards due to assembling Hazard Division 1.3G and 1.4G explosives consisting of display fireworks and electric igniters (e-matches), in that a pre-start-up safety review was not performed.
Recent events (3)
  • — R (S) $0
  • — C (S) $14518
  • — Z (S) $14518

1910.119 N

Serious Gravity 10 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $14518.00 · Current $13066.00 Reduced
29 CFR  1910.119(n): The employer did not implement an emergency plan for the entire plant in accordance with the provisions of 29 CFR 1910.38:  a.) At 1500 Masters Blvd, Champions Gate, FL: On or about February 19, 2024, employees were exposed to explosion, deflagration, and fire hazards due to assembling Hazard Division 1.3G and 1.4G explosives consisting of display fireworks and electric igniters (e-matches), in that in that an emergency plan had not been established.
Recent events (3)
  • — R (S) $13066
  • — C (S) $14518
  • — Z (S) $14518

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347315178.