EAST HARTFORD, CT —
OSHA Inspection: SHERWIN WILLIAMS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SHERWIN WILLIAMS, INC. in 95 GOODWIN STREET, EAST HARTFORD, CT 06108 (NAICS 325510). OSHA activity number 347337339.
Where did this inspection happen?
- Establishment
- SHERWIN WILLIAMS, INC.
- Site address
- 95 GOODWIN STREET
- City
- EAST HARTFORD
- State
- CT
- ZIP
- 06108
- Mailing
- 95 GOODWIN STREET, EAST HARTFORD, CT 06108
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325510
- Employees
- 66
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.106 D02 III
- Issued
- Abate by
- Penalty
- Initial $7604.00 · Current $4500.00 Reduced
General-duty citation text
29 CFR 1910.106(d)(2)(iii): Flammable or combustible liquid containers were not stored in accordance with Table H-12: Quality Lab: On, or about, March 8, 2024, the following Category 2 flammable liquids were stored in plastic one-gallon containers. The maximum size permitted in Table H-12 was one quart: A. Isopropyl Alcohol. B. Dur-A-Solve.
Recent events (2)
- — I (S) $4500
- — Z (S) $7604
1910.106 E02 IV C
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(c): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 �F (37.8 �C), were used where there were open flames or other sources of ignition within the possible path of vapor travel: Quality Lab: On, or about, March 8, 2024, potential ignition sources were used without first evaluating whether the sources of ignition were within the possible path of vapor travel. A. Dur-A-Solve, a Category 2 flammable liquid was used to clean the paddle on the Caframo Model 3030 lab stirrer: 1. The wall mounted receptacle used to energize the lab stirrer. 2. The motor provided on the lab stirrer. B. Isopropyl alcohol, a Category 2 flammable liquid was used to clean the probe on the DV Plus viscometer. A wall mounted receptacle used to energize the viscometer.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.212 A01
- Issued
- Penalty
- Initial $6464.00 · Current $4500.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts: Quality Lab: On, or about, March 8, 2024, a guard was not provided on the rotating chuck on the Cafrano Model 3030 Universal stirrer.
Recent events (2)
- — I (S) $4500
- — Z (S) $6464
1910.1200 F06 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: Quality Lab: On, or about, March 8, 2024, a plastic one-gallon container was used to store Isopropyl Alcohol, a Category 2 flammable liquid. The container was labeled as both Isopropyl Alcohol and Ethanol.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at SHERWIN WILLIAMS, INC.
Weirton, WV—1975-02-05
SHERWIN WILLIAMS INC
View SHERWIN WILLIAMS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325510)
HEALDSBURG, CA—2026-07-08
RUPERT GIBBON & SPIDER, INC.
ROCKLEDGE, FL—2026-06-24
RICHARD'S PAINT MANUFACTURING CO
ROCHESTER, PA—2026-06-18
THE SHERWIN-WILLIAMS COMPANY
AUBURN, CA—2026-06-15
PRESERVA PRODUCTS LTD
FAIRLESS HILLS, PA—2026-06-09
SUDARSHAN FAIRLESS HILLS MANUFACTURING
More inspections in CT
BRIDGEPORT, CT—2026-07-10
WRR, INC.
BERLIN, CT—2026-07-10
MMF CONSTRUCTION LLC
NAUGATUCK, CT—2026-07-08
WHITING-TURNER LCT2 JOINT VENTURE
SOMERS, CT—2026-07-08
F&G RECYCLING LLC
STAMFORD, CT—2026-07-07
FAIRFIELD AVENUE MAINTENANCE COMPANY, INC.
Source