On , OSHA opened a complaint safety inspection of HYPRO, INC. in 1111 AIR PARK RD, RHINELANDER, WI 54501 (NAICS 332999). OSHA activity number 347340234.

Watch Hypro, INC. — free Get an email when a new federal OSHA severe-injury report for Hypro, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
HYPRO, INC.
Site address
1111 AIR PARK RD
City
RHINELANDER
State
WI
ZIP
54501
Mailing
1111 AIR PARK RD, RHINELANDER, WI 54501
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
40
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 5 instances 5 exposed
Issued
Penalty
Initial $7835.00 · Current $5485.00 Reduced
29 CFR  1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices, electronic safety devices, etc.  On or about March 12, 2024, at an establishment located at 1111 Air Park Road in Rhinelander, Wisconsin, employees of Hypro, Inc. were not provided machine guarding to protect operators and other employees in the machine areas from hazards, such but not limited to:  a)  The employer did not protect employees from an ingoing nip point on a parts conveyor in the east building on RLC3.  b)  The employer did not protect employees from an ingoing nip point on a parts conveyor in the east building on RLC4.  c)  The employer did not protect employees from an exposed auger in the south building on R37.  d)  The employer did not protect employees from a rotating machine part in the north building on machine 295.  e)  The employer did not protect employees from rotating machine parts in the north building on the hobbing machine 412.  f)  The employer did not protect employees from rotating machine parts in the east building on the machine 288 grinder.
Recent events (2)
  • — I (S) $5484.5
  • — Z (S) $7835

1910.303 B02

Serious Gravity 5 4 instances 3 exposed
Issued
Penalty
Initial $9795.00 · Current $6857.00 Reduced
29 CFR  1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.  At an establishment located at 1111 Air Park Road in Rhinelander, Wisconsin, employees of Hypro, Inc. were exposed to electrical and fire hazards utilizing listed equipment not in accordance with the instructions for a Relocatable Power Tap (RPT) that was not designed to be installed in an industrial setting in the following settings:  a)  On or about March 12, 2024, employees in the south building were exposed to electrical and shock hazards near RO1 Vertical Milling Center.  b)  On or about March 12, 2024, employees in the south building were exposed to electrical and shock hazards near Machine 276 Horizontal Lathe.  c)  On or about March 12, 2024, employees in the south building were exposed to electrical and shock hazards near Machine R51 Horizontal Lathe.  d)  On or about March 12, 2024, employees in the north building were exposed to electrical and shock hazards near Machine 303 Horizontal Lathe.
Recent events (2)
  • — I (S) $6856.5
  • — Z (S) $9795

1910.305 B01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed.  On or about March 12, 2024, at an establishment located at 1111 Air Park Road in Rhinelander, Wisconsin, employees of Hypro, Inc. were exposed to electrical shock and burn hazards when the employer did not protect employees from electrical hazards in the South Building on Machine R37 Horizontal Milling Machine where conductors entered a junction box on a motor with the fitting pulled out of the junction box, exposing the wires to abrasion.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.334(a)(2)(ii): If there is a defect or evidence of damage that might expose an employee to injury, the defective or damaged item shall be removed from service, and no employee may use it until repairs and tests necessary to render the equipment safe have been made.  On or about March 12, 2024, at an establishment located at 1111 Air Park Road in Rhinelander, Wisconsin, employees of Hypro, Inc. were exposed to electrical shock and burn hazards when the employer did not protect employees from electrical hazards in the South Building on Machine R58 Lathe where an exposed ground conductor was present on a flexible cord.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View HYPRO, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347340234.