Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JR NEW ENERGY INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JR NEW ENERGY INC. in 3201 NORTH SYLVANIA AVENUE, FORT WORTH, TX 76111 (NAICS 334419). OSHA activity number 347356032.

Watch JR NEW Energy INC. — free Get an email when a new federal OSHA severe-injury report for JR NEW Energy INC. is published. One employer, no account, unsubscribe in one click.
Establishment
JR NEW ENERGY INC.
Site address
3201 NORTH SYLVANIA AVENUE
City
FORT WORTH
State
TX
ZIP
76111
Mailing
3201 NORTH SYLVANIA AVENUE, FORT WORTH, TX 76111
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334419
Employees
48
Ownership type
A

5 citations on file for this inspection.

1910.178 M03

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $11292.00 · Current $11292.00
29 CFR 1910.178(m)(3): Unauthorized personnel were permitted to ride on industrial truck(s):   On or about March 15, 2024, employees were allowed to ride on forklifts in the following instances:  a)  employees were allowed to be elevated on the forks of the forklift, such as but not limited to, replacing a fuse on a crane while standing on a pallet supported by a forklift exposing the employees to fall hazards, and  b) employees were allowed to ride on the forklift with the operator during training on the forklift and other activities exposing employees to falling hazards and struck-by hazards.
Recent events (1)
  • — Z (S) $11292

1910.184 E01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
Citation amended to read as follows: 29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach:  On or about March 19, 2024, and at times prior thereto, the employer did not ensure all steel chain slings being utilized to lift loads had an identification tag permanently attached.
Recent events (1)
  • — Z (O) $0

1910.305 B02

Other-than-serious 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  On or about March 19, 2024, and at times prior thereto the employer did not ensure electrical junction boxes were covered to protect against electrical shock.
Recent events (1)
  • — Z (O) $0

1910.333 B02 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.333(b)(2)(i): The employer did not maintain a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 and did not make it available for inspection by the Assistant Secretary of Labor and his or her authorized representatives:  on or about March 19, 2024, and at times prior the employer did not maintain a written energy control procedures for electrical equipment to deenergize circuits and equipment exposing employees to electric shock hazards.
Recent events (1)
  • — Z (O) $0

1910.334 A02 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) was not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord and plug connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated.  On or about March 19, 2024, and at times prior thereto, the employer did not ensure each portable cord and plug connected equipment was visually inspected before use on any shift for external defects.
Recent events (1)
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347356032.