Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: YMH, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of YMH, INC. in SENDERO RIG #103 11 MILES NE DIRECTION FROM GARDENDALE TX, ANDREWS, TX 79714 (NAICS 213112). OSHA activity number 347374753.

Watch YMH, INC. — free Get an email when a new federal OSHA severe-injury report for YMH, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
YMH, INC.
Site address
SENDERO RIG #103 11 MILES NE DIRECTION FROM GARDENDALE TX
City
ANDREWS
State
TX
ZIP
79714
Mailing
4830 EAST SEMINOLE HIGHWAY, HOBBS, NM 88240
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
8
Ownership type
A

4 citations on file for this inspection.

1910.304 G05

Serious Gravity 5 5 instances 8 exposed
Issued
Abate by
Penalty
Initial $4702.00 · Current $4702.00
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:  a) On or about March 27, 2024, Trailer #2226; employee(s) were utilizing the trailer which was not effectively grounded. The trailer was used for sleeping quarters.   b) On or about March 27, 2024, Mud Engineer's Trailer #6967; employee(s) were utilizing the trailer which was not effectively grounded. The trailer was used for sleeping quarters.   c) On or about March 27, 2024, Directional Driller's Trailer #6971; employee(s) were utilizing the trailer which was not effectively grounded. The trailer was used for sleeping quarters.  d) On or about March 27, 2024, Command CenterTrailer #9916;  employee(s) utilized the trailer which was not effectively grounded. The trailer was used for daily meetings.  e) On or about March 27, 2024, Dragon Water Tank; employee(s) were utilizing the water tank which was not effectively grounded. The water tank was used to supply water to the trailer sewage systems.
Recent events (1)
  • — Z (S) $4702

1910.305 B01 II

Other-than-serious 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $440.00 · Current $440.00
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  On or about March 27, 2024, outside of the Night Company Man's Trailer #2226; employee(s) utilized the trailer's air conditioning (A/C) unit powered by an electrical circuit box with an unused opening underneath while the A/C unit was being used.
Recent events (1)
  • — Z (O) $440

1910.305 B02 I

Other-than-serious 4 instances 8 exposed
Issued
Abate by
Penalty
Initial $440.00 · Current $440.00
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  a) On or about March 27, 2024, on front side of Day Company Man's Trailer #3364, employee(s) utilized a 2-outlet outdoor receptacle that did not have a faceplate while using the receptacle to power equipment.   b) On or about March 27, 2024, on the side of  the Command Center Trailer #5651, employee(s) utilized a 2-outlet outdoor receptacle that did not have a faceplate while using the receptacle to power equipment.  c) On or about March 27, 2024, on the front side of Mud Engineer'sTrailer #6967, employee(s) utilized a 2-outlet outdoor receptacle that did not have a faceplate while using the receptacle to power equipment.   d) On or about March 27, 2024, on the side of the Directional Driller Trailer #6971, employee(s) utilized a 2-outlet outdoor receptacle that did not have a faceplate while using the receptacle to power equipment.
Recent events (1)
  • — Z (O) $440

1910.305 G02 III

Other-than-serious 3 instances 5 exposed
Issued
Abate by
Penalty
Initial $440.00 · Current $440.00
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  a) On or about March 27, 2024, outside of the Night Company Man's Trailer #2226; employee(s) were utilizing the trailer's air conditioning (A/C) unit with a power cable that had a broken strain relief going into the main electrical circuit box.   b) On or about March 27, 2024, outside of Mud Engineer's Trailer #6967; employee(s) were utilizing the trailer's air conditioning (A/C) unit with a power cable that had a broken strain relief going into the main electrical circuit box.   c) On or about March 27, 2024, outside of Directional Driller's Trailer #6971;  employee(s) were utilizing the trailer's air conditioning (A/C) unit with a power cable that had a broken strain relief going into the main electrical circuit box.
Recent events (1)
  • — Z (O) $440