Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JNBA CONSTRUCTION CONSULTING

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of JNBA CONSTRUCTION CONSULTING in UNIVERSITY OF THE VIRGIN ISLANDS CAMPUS 1-B AND 2 GOLDEN GROVE, FREDERIKSTED, VI 00840 (NAICS 236220). OSHA activity number 347386419.

Watch Jnba Construction Consulting — free Get an email when a new federal OSHA severe-injury report for Jnba Construction Consulting is published. One employer, no account, unsubscribe in one click.
Site address
UNIVERSITY OF THE VIRGIN ISLANDS CAMPUS 1-B AND 2 GOLDEN GROVE
City
FREDERIKSTED
State
VI
ZIP
00840
Mailing
P.O. BOX 965, FREDERIKSTED, VI 00841
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
236220
Employees
12
Ownership type
A

3 citations on file for this inspection.

1926.350 A09

Serious Gravity 5 1 instance 8 exposed
Issued
Penalty
Initial $3134.00 · Current $2037.00 Reduced
29 CFR  1926.350(a)(9): Compressed gas cylinders were not secured in an upright position at all times:  (a) On or about April 2, 2024, University of the Virgin Islands Campus 1-B and 2 Golden Grove Frederiksted, VI  00840, two oxygen cylinders and one acetylene tank were lying on the ground, exposing employees to a projectile and explosion hazards.  NOTE: Certification of abatement is not required for this citation item, as abatement was documented by the compliance safety and health officer during the inspection.
Recent events (2)
  • — I (S) $2037.1
  • — Z (S) $3134

1926.351 B04

Serious Gravity 10 1 instance 8 exposed
Issued
Penalty
Initial $6452.00 · Current $4194.00 Reduced
29 CFR  1926.351(b)(4): Welding cable(s) in use were in need of repair:   (a) On or about April 2, 2024, at University of the Virgin Islands Campus 1-B and 2 Golden Grove Frederiksted, VI  00840, a welder was set to use welding cables in need of repair, exposing employees to electrical hazards.  NOTE: Certification of abatement is not required for this citation item, as abatement was documented by the compliance safety and health officer during the inspection.
Recent events (2)
  • — I (S) $4193.8
  • — Z (S) $6452

1926.1053 B01

Serious Gravity 5 1 instance 8 exposed
Issued
Penalty
Initial $3918.00 · Current $2547.00 Reduced
29 CFR 1926.1053(b)(1): Because of the portable ladder's length, the ladder side rails did not extend to at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access, and the ladder was not secured at its top to a rigid support.  (a) On or about April 2, 2024, University of the Virgin Islands Campus 1-B and 2 Golden Grove Frederiksted, VI  00840, employees used an extension ladder (18 Ft Ladder) to gain access and as a means of egress to the working platform approximately 14 feet high. The ladder was not secured to a rigid structure at its top, exposing employees to a fall hazard.  NOTE: Certification of abatement is not required for this citation item, as abatement was documented by the compliance safety and health officer during the inspection.
Recent events (2)
  • — I (S) $2546.7
  • — Z (S) $3918

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347386419.