CAMP PENDLETON, CA —
OSHA Inspection: BJS & T ENTERPRISES INC
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of BJS & T ENTERPRISES INC in BLDG 31C20T (TFS), DONALD COOK RD, CAMP PENDLETON, CA 92055 (NAICS 336611). OSHA activity number 347401481.
Where did this inspection happen?
- Establishment
- BJS & T ENTERPRISES INC
- Site address
- BLDG 31C20T (TFS), DONALD COOK RD
- City
- CAMP PENDLETON
- State
- CA
- ZIP
- 92055
- Mailing
- 1702 MAGNOLIA AVENUE, EL CAJON, CA 92020
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336611
- Employees
- 7
- Ownership type
- A
Citations
4 citations on file for this inspection.
1915.7 C05
- Issued
- Abate by
- Penalty
- Initial $8067.00 · Current $4114.00 Reduced
General-duty citation text
29 CFR 1915.7(c)(5): The employer did not ensure that each designated competent person had the ability to perform all required tests and inspections which may be performed by a competent person as set forth in 29 CFR 1915 Subparts B, C, D, and H. Camp Pendleton, Bldg. 31C20T, Temporary Fabric Shelter, LCAC 90, Fuel Cell #1: On and/or before April 9th, 2024, the employer did not provide confined space monitoring equipment to designated competent persons to test confined spaces. The competent person was not able to perform all required tests as set forth in 29 CFR 1915 Subparts B, C, D, and H. Employee(s) were potentially exposed to confined space atmospheric hazard(s).
Recent events (2)
- — I (O) $4114
- — Z (S) $8067
1915.13 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1915.13(b)(2): Testing was not conducted by a competent person to determine the concentration of flammable, combustible, toxic, corrosive, or irritant vapors within the space prior to the beginning of cleaning or cold work. Camp Pendleton, Bldg. 31C20T, Temporary Fabric Shelter, LCAC 90, Fuel Cell #1: On and/or before April 9th, 2024, the employer did not ensure that the #1 fuel cell was tested by a shipyard competent person to determine the concentration of flammable, combustible, toxic, corrosive, or irritant vapors within the space prior to the beginning of painting operations. Employee(s) were potentially exposed to confined space atmospheric hazard(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1915.13 B04
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1915.13(b)(4): Testing was not conducted by the competent person as often as necessary during cleaning or cold work to assure that air concentrations were below 10 percent of the lower explosive limit, within the Permissible Exposure Limit (PEL), and below Immediately Dangerous to Life and Health (IDLH) levels. Camp Pendleton, Bldg. 31C20T, Temporary Fabric Shelter, LCAC 90, Fuel Cell #1: On and/or before April 9th, 2024, testing was not conducted while employee(s) were painting inside a confined space by a shipyard competent person to assure that air concentrations were below 10 percent of the lower explosive limit, within the Permissible Exposure Limit (PEL), and below Immediately Dangerous to Life and Health (IDLH) levels. Employee(s) were potentially exposed to confined space atmospheric hazard(s).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1915.36 A06
- Issued
- Abate by
- Penalty
- Initial $11292.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1915.36(a)(6): In areas where liquid solvents, paint and preservative coating removers, paints or vehicles were capable of producing a flammable atmosphere under the conditions of use, suitable fire extinguishing equipment was not immediately available in the work areas. Camp Pendleton, Bldg. 31C20T, Temporary Fabric Shelter, LCAC 90, Fuel Cell #1: The employees mixed and used a Seaguard 5000 part A/B epoxy coating (category 3 flammable), a suitable fire extinguisher was not immediately available in the work area. This condition potentially exposed employees to fire hazard(s).
Recent events (2)
- — I (S) $0
- — Z (S) $11292
More inspections at BJS & T ENTERPRISES INC
CAMP PENDLETON, CA—2024-04-09 00:00:00
BJS & T ENTERPRISES INC
View BJS & T ENTERPRISES INC's full OSHA safety record →
More inspections in this industry (NAICS 336611)
AMELIA, LA—2026-07-10
CONRAD SHIPYARD, LLC
PORTSMOUTH, VA—2026-07-09
PALFINGER MARINE USA INC.
STUART, FL—2026-07-07
APPLIED CONCEPTS UNLEASHED, INC.
VANCOUVER, WA—2026-07-02
WA317991919 - JT MARINE INC
STUART, FL—2026-07-02
OCEAN MASTERS MARINE
More inspections in CA
IRVINE, CA—2026-07-13
SNEARY CONSTRUCTION, INC.
IRVINE, CA—2026-07-13
KUKBO DESIGN USA LLC
ENCINITAS, CA—2026-07-13
LOU RIDDLE CONSTRUCTION
CANYON COUNTRY, CA—2026-07-13
COLLEGE OF THE CANYONS
LINDSAY, CA—2026-07-13
NATIONAL DIVERSIFIED SALES, INC.
Source