Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BJS & T ENTERPRISES INC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of BJS & T ENTERPRISES INC in BLDG 31C20T (TFS), DONALD COOK RD, CAMP PENDLETON, CA 92055 (NAICS 336611). OSHA activity number 347401481.

Watch BJS & T Enterprises INC — free Get an email when a new federal OSHA severe-injury report for BJS & T Enterprises INC is published. One employer, no account, unsubscribe in one click.
Site address
BLDG 31C20T (TFS), DONALD COOK RD
City
CAMP PENDLETON
State
CA
ZIP
92055
Mailing
1702 MAGNOLIA AVENUE, EL CAJON, CA 92020
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
7
Ownership type
A

4 citations on file for this inspection.

1915.7 C05

Other-than-serious Gravity 5 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $8067.00 · Current $4114.00 Reduced
29 CFR 1915.7(c)(5): The employer did not ensure that each designated competent person had the ability to perform all required tests and inspections which may be performed by a competent person as set forth in 29 CFR 1915 Subparts B, C, D, and H.  Camp Pendleton, Bldg. 31C20T, Temporary Fabric Shelter, LCAC 90, Fuel Cell #1: On and/or before April 9th, 2024, the employer did not provide confined space monitoring equipment to designated competent persons to test confined spaces. The competent person was not able to perform all required tests as set forth in 29 CFR 1915 Subparts B, C, D, and H. Employee(s) were potentially exposed to confined space atmospheric hazard(s).
Recent events (2)
  • — I (O) $4114
  • — Z (S) $8067

1915.13 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1915.13(b)(2): Testing was not conducted by a competent person to determine the concentration of flammable, combustible, toxic, corrosive, or irritant vapors within the space prior to the beginning of cleaning or cold work.  Camp Pendleton, Bldg. 31C20T, Temporary Fabric Shelter, LCAC 90, Fuel Cell #1: On and/or before April 9th, 2024, the employer did not ensure that the #1 fuel cell was tested by a shipyard competent person to determine the concentration of flammable, combustible, toxic, corrosive, or irritant vapors within the space prior to the beginning of painting operations. Employee(s) were potentially exposed to confined space atmospheric hazard(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1915.13 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1915.13(b)(4): Testing was not conducted by the competent person as often as necessary during cleaning or cold work to assure that air concentrations were below 10 percent of the lower explosive limit, within the Permissible Exposure Limit (PEL), and below Immediately Dangerous to Life and Health (IDLH) levels.  Camp Pendleton, Bldg. 31C20T, Temporary Fabric Shelter, LCAC 90, Fuel Cell #1: On and/or before April 9th, 2024, testing was not conducted while employee(s) were painting inside a confined space by a shipyard competent person to assure that air concentrations were below 10 percent of the lower explosive limit, within the Permissible Exposure Limit (PEL), and below Immediately Dangerous to Life and Health (IDLH) levels. Employee(s) were potentially exposed to confined space atmospheric hazard(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1915.36 A06

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $11292.00 · Current $0.00 Reduced
29 CFR  1915.36(a)(6): In areas where liquid solvents, paint and preservative coating removers, paints or vehicles were capable of producing a flammable atmosphere under the conditions of use, suitable fire extinguishing equipment was not immediately available in the work areas.   Camp Pendleton, Bldg. 31C20T, Temporary Fabric Shelter, LCAC 90, Fuel Cell #1: The employees mixed and used a Seaguard 5000 part A/B epoxy coating (category 3 flammable), a suitable fire extinguisher was not immediately available in the work area. This condition potentially exposed employees to fire hazard(s).
Recent events (2)
  • — I (S) $0
  • — Z (S) $11292

View BJS & T ENTERPRISES INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347401481.