SAVANNAH, GA —
OSHA Inspection: CELADON DP, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CELADON DP, LLC in 48 ARTLEY RD, SAVANNAH, GA 31408 (NAICS 423930). OSHA activity number 347408809.
Where did this inspection happen?
- Establishment
- CELADON DP, LLC
- Site address
- 48 ARTLEY RD
- City
- SAVANNAH
- State
- GA
- ZIP
- 31408
- Mailing
- 48 ARTLEY RD, SAVANNAH, GA 31401
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 16
- Ownership type
- A
Citations
9 citations on file for this inspection.
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $6857.00 · Current $4114.00 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a fire/deflagration hazard. A) East wall of building located at 48 Artley Rd, in Savannah GA: On or about April 10, 2024, the employer exposed employees to a fire/deflagration hazard, in that the upper areas were allowed to accumulate dust greater than 1/32 of an inch deep and that an electrical blowers , such as a Craftsman CMEBL710 and/or a Toro 51624 that were not rated for Class II locations was used to remove dust from upper areas.
Recent events (2)
- — I (S) $4114.2
- — Z (S) $6857
5(a)(1)
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that the employees were exposed to a fire/deflagration hazard. A) East wall of building located at 48 Artley Rd, in Savannah GA: On or about April 10, 2024, the employer exposed employees to a fire/deflagration hazard, in that the cleaning schedule did not prevent the accumulation of dust from building up to greater than 1/32 of an inch deep on electrical equipment and motors.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. A) Production area located at 48 Artley Rd., Savannah,GA: On or about April 10, 2024, and times prior thereto, the employer exposed employees to a fire hazard, in that paper dust was allowed to accumulate on the wall, piping, electrical equipment and on other surfaces along the east wall.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.28 B03 IV
- Issued
- Abate by
- Penalty
- Initial $5485.00 · Current $3291.00 Reduced
General-duty citation text
29 CFR 1910.28(b)(3)(iv): The employer did not provide that each employee be protected from falling into a ladderway floor hole or ladderway platform hole by a guardrail system and toeboards erected on all exposed sides, except at the entrance to the hole, where a self-closing gate or an offset must be used. A) Wire cutting platform located at East wall of building located at 48 Artley Rd, in Savannah GA: On or about April 10, 2024, the employer exposed employees to a fall hazard, in that there was not a self-closing gate or offset where the opening to the ladder was located.
Recent events (2)
- — I (S) $3291
- — Z (S) $5485
1910.106 G08
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.106(g)(8): Conspicuous and legible signs prohibiting smoking were not posted. A) East side of building located at 48 Artley Rd. Savannah, GA: On or about April 10, 2024, the employer exposed employees to a fire hazard, in that there was not a "NO SMOKING" sign posted at the above ground diesel fuel tank.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(c)(1):A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: A) In the production area located at 48 Artley Rd, in Savannah GA: On or about April 10, 2024, and at times prior to, the employer exposed employees to respiratory hazards, in that the employer did not establish a written respiratory program for employees who wore negative pressure respirators and filtering face piece respirators.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 C02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: A) In the production area located at 48 Artley Rd, in Savannah GA: On or about April 10, 2024, and at times prior to, the employer exposed employees to respiratory hazards, in that the employer did not inform the employees who voluntarily wore a filtering face piece respirator on Appendix "D".
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: A) In the production area located at 48 Artley Rd, in Savannah GA: On or about April 10, 2024, and at times prior to, the employer exposed employees to respiratory hazards, in that the employer did not provide a medical evaluation before employees were fit tested or required to use respiratory protection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 K
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(k): The employer did not provide to employees required to use respirators, annual and more often if necessary, effective respiratory protection training that was comprehensive and understandable: A) In the production area located at 48 Artley Rd, in Savannah GA: On or about April 10, 2024, and at times prior to, the employer exposed employees to respiratory hazards, in that the employer did not provide comprehensive, understandable training to employees required to use respiratory protection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at CELADON DP, LLC
PASADENA, TX—2026-01-28
CELADON DP, LLC
PASADENA, TX—2025-05-06
CELADON DP, LLC
PASADENA, TX—2025-05-01
CELADON DP, LLC
PASADENA, TX—2024-10-24 00:00:00
CELADON DP, LLC
SAVANNAH, GA—2024-06-12 00:00:00
CELADON DP, LLC
View CELADON DP, LLC's full OSHA safety record →
More inspections in this industry (NAICS 423930)
OGDEN, UT—2026-07-10
TEAR A PART AUTO RECYCLING
GARNER, NC—2026-07-09
161490 - CAROLINA METAL RECYCLERS, LLC
JOPLIN, MO—2026-07-07
SERVICE RECYCLING - NORTH PLANT
HOLBROOK, NY—2026-07-01
ARROW SCRAP CORPORATION
DOVER, OH—2026-07-01
SPEEDIE AUTO SALVAGE
More inspections in GA
ROME, GA—2026-07-13
CAMP INDUSTRIES
SOUTH FULTON, GA—2026-07-10
REEDWICK, LLC
CONYERS, GA—2026-07-10
GOLDEN STATE FOODS
DALTON, GA—2026-07-10
ENGINEERED FLOORS, LLC
METTER, GA—2026-07-10
M.A.P.C CONSTRUCTION, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347408809.