ALBION, NY —
OSHA Inspection: PENASACK MACHINE CO., INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PENASACK MACHINE CO., INC. in 49 SANFORD STREET, ALBION, NY 14411 (NAICS 332322). OSHA activity number 347432957.
Where did this inspection happen?
- Establishment
- PENASACK MACHINE CO., INC.
- Site address
- 49 SANFORD STREET
- City
- ALBION
- State
- NY
- ZIP
- 14411
- Mailing
- PO BOX 70, ALBION, NY 14411
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 12
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $3457.00 · Current $2593.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 04/23/2024 in the production area; where the company has hazardous energy control procedures for equipment such as, but not limited to turret punch press, laser cutting machine press brakes and band saws. The last documented review/revision of the procedures was in 2011. The employer did not have documentation of any review that may have occurred since 2011. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2592.75
- — Z (S) $3457
1910.147 C06 I C
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C):Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected: a) On or about 04/23/2024 in the production areas: where the "authorized employees" have not been observed and certified while performing a lockout procedure in the last several years. No certification was available for the most recent periodic evaluation of "authorized employees". Employees perform servicing/maintenance on machines and equipment such as, but not limited to : turret punch press, press brakes, and horizontal band saw. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at PENASACK MACHINE CO., INC.
ALBION, NY—2019-06-21 00:00:00
PENASACK MACHINE CO., INC.
Albion, NY—1983-07-28
PENASACK MACHINE CO INC
View PENASACK MACHINE CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332322)
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
PITTSBURG, KS—2026-07-09
PROGRESSIVE PRODUCTS INC
NEW ROCHELLE, NY—2026-07-09
HEFTI HARBOR ELEC FAB & TOOLS
LAKEWOOD, WA—2026-07-08
WA317992020 - KRUEGER SHEET METAL CO
SOUTHAMPTON, MA—2026-07-07
LYMAN SHEET METAL CO., INC
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347432957.