On , OSHA opened a planned safety inspection of JJE CONCRETE, LLC in 3800 CHARCO ROAD, BEEVILLE, TX 78102 (NAICS 238110). OSHA activity number 347444408.

Watch JJE Concrete, LLC — free Get an email when a new federal OSHA severe-injury report for JJE Concrete, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
JJE CONCRETE, LLC
Site address
3800 CHARCO ROAD
City
BEEVILLE
State
TX
ZIP
78102
Mailing
207 WEST EVERGREEN STREET, UVALDE, TX 78801
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238110
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $4839.00 · Current $4839.00
29 CFR  1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.   On or about April 25, 2024, and times prior thereto, employees dismantled recently poured concrete column forms at the height of greater than 7-13 feet.  Employees used the first-tier scaffold cross braces as a means off access.
Recent events (1)
  • — Z (S) $4839

1926.451 G01 VII

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $4839.00 · Current $4839.00
29 CFR  1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  On or about April 25, 2024, and times prior thereto, employees dismantled column forms greater than 10 feet above a lower level.  Employees were not protected from falls by the use of personal fall arrest systems or guard railing systems on the scaffolds.