On , OSHA opened an unprogrammed Other safety inspection of CHAVAS HOME IMPROVEMENT in 778 LEXINGTON DRIVE, HERMITAGE, PA 16148 (NAICS 238160). OSHA activity number 347456477.

Watch Chavas Home Improvement — free Get an email when a new federal OSHA severe-injury report for Chavas Home Improvement is published. One employer, no account, unsubscribe in one click.
Site address
778 LEXINGTON DRIVE
City
HERMITAGE
State
PA
ZIP
16148
Mailing
1659 MIDLAND AVENUE, YOUNGSTOWN, OH 44501
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
5
Ownership type
A

6 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4839.00 · Current $3000.00 Reduced
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system:  A) Chavas Home Improvement on or about May 02, 2024 at the address of 778 Lexington Drive, Hermitage, PA: Employees were performing roofing activities roughly 20 feet above the ground on the flat portion of the roof without any type of fall protection.
Recent events (2)
  • — I (S) $3000
  • — Z (S) $4839

1926.502 E02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3457.00 · Current $2000.00 Reduced
29 CFR  1926.502(e)(2): Positioning devices were not secured to an anchorage capable of supporting at least twice the potential impact load of an employee's fall or 3,000 pounds (13.3 kN), whichever was greater:  A) Chavas Home Improvement on or about May 02, 2024 at the address of 778 Lexington Drive, Hermitage, PA: Employees were not properly using the positioning device while employees  conducted roofing work on the side of the structure. The employee was using a positioning device that was nailed to the roof directly through the ropes, causing damage to the strands of the rope.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $3457

1926.20 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.20(b)(2):The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person.  A) Chavas Home Improvement on or about May 02, 2024 at the address of 778 Lexington Drive, Hermitage, PA: Inspections were not done on the fall prevention systems, due to nails being driven through the positioning device ropes and were being used as an anchorage point.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.20 B03

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.20(b)(3):Machinery, tool(s), material(s), or equipment which was not in compliance with the applicable requirement(s) of 29 CFR 1926 was not prohibited, and/or was not either identified as unsafe by tagging, or locking the controls to render them inoperable, or physically removed from its place of operation.  A) Chavas Home Improvement on or about May 02, 2024 at the address of 778 Lexington Drive, Hermitage, PA: The anchorage ropes for the positioning devices were damaged, due to nails being driven through the ropes and they were still being used as a fall prevention system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.503 A02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.503(a)(2)(ii):The employer did not assure that each employee, as necessary, had been trained by a competent person in the correct procedures for erecting, maintaining, disassembling and inspecting the fall protection systems to be used:  A) Chavas Home Improvement on or about May 02, 2024 at the address of 778 Lexington Drive, Hermitage, PA: Employees were not trained in inspecting the fall prevention system equipment before the use of the equipment. Employees were using incorrect fall restraint systems onsite the day of the inspection, ropes were damaged from improper assembly of the equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2074.00 · Current $1000.00 Reduced
29 CFR  1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  A) Chavas Home Improvement on or about May 02, 2024 at the address of 778 Lexington Drive, Hermitage, PA: Employees using the ladder on the front of the building did not have the ladder extended 3 feet above the landing surface. The ladder was extended roughly 1 foot above the landing surface.