Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JT MANUFACTURING LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of JT MANUFACTURING LLC in 300 E STEWART STREET, WILLIS, TX 77378 (NAICS 332999). OSHA activity number 347473191.

Watch JT Manufacturing LLC — free Get an email when a new federal OSHA severe-injury report for JT Manufacturing LLC is published. One employer, no account, unsubscribe in one click.
Site address
300 E STEWART STREET
City
WILLIS
State
TX
ZIP
77378
Mailing
502 W. MONTGOMERY #403, WILLIS, TX 77378
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
332999
Employees
3
Ownership type
A

6 citations on file for this inspection.

1910.22 A01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4148.00 · Current $0.00 Reduced
29 CFR 1910.22(a)(1): The employer did not ensure that all places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition.  On or about May 13, 2024, in the western and northern edge of the metal shop, numerous large metal parts and trash was scattered all over the floor, blocking walkways and egress routes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4148

1910.252 A02 IX

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $4839.00 · Current $2661.00 Reduced
29 CFR  1910.252(a)(2)(ix): Where cutting or welding was done near walls, partitions, ceiling or roof of combustible construction, fire-resistant shields or guards were not provided to prevent ignition.  On or about May 13, 2024, on the southern wall of the Welding Shop, employees were conducting welding and hot metal work next to treated plywood walls.
Recent events (2)
  • — I (S) $2661.45
  • — Z (S) $4839

1910.253 B02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior.  On or about May 13, 2024, in the eastern part of the Welding Shop, employees were working in close proximity to compressed gas tanks that are being stored within 20' of combustible materials.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B02 IV

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use.  On or about May 13, 2024, on the southern wall of the Welding Shop, employees were conducting welding and hot metal work next to compressed gas tanks that are missing their safety caps.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.254 D09 III

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2765.00 · Current $2765.00
29 CFR  1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replace.  On or about May 10, 2024, in the welding area of the Machine Shop, the Metal Inert Gas (MIG) welder's conductor cable has exposed metal wires, while the worker was welding.
Recent events (2)
  • — I (S) $2765
  • — Z (S) $2765

1910.303 B02

Serious Gravity 5 3 instances 3 exposed
Issued
Abate by
Penalty
Initial $2765.00 · Current $0.00 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.  On or about May 13, 2024, in multiple areas within the Welding Shop, employees were conducting welding and hot metal work next to electrical equipment being powered by flexible cords:  Instance A.  Along the north wall, approximately 12' off the ground, an (unknown brand) Wall Exhaust Fan was powered by an orange in color extension cord.   Instance B. Along the south wall, approximately 12' off the ground, an (unknown brand) Wall Exhaust Fan was powered by an orange in color extension cord.   Instance C. Along the western wall of the Welding shop, a Craftsman Bench Grinder was powered by an orange in color extension cord.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2765

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347473191.