STOUGHTON, MA —
OSHA Inspection: PRECISION FABRICATORS LTD. LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of PRECISION FABRICATORS LTD. LLC in 171 TOSCA DRIVE, STOUGHTON, MA 02072 (NAICS 332439). OSHA activity number 347484974.
Where did this inspection happen?
- Establishment
- PRECISION FABRICATORS LTD. LLC
- Site address
- 171 TOSCA DRIVE
- City
- STOUGHTON
- State
- MA
- ZIP
- 02072
- Mailing
- 171 TOSCA DRIVE, STOUGHTON, MA 02072
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332439
- Employees
- 18
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C01
- Issued
- Penalty
- Initial $4610.00 · Current $2305.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1):The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. Location 171 Tosca Drive, Stoughton MA On or about May 16, 2024 employees were exposed to potential amputation hazards where lathes, mills and CNC machines were used and a LOTO program was not established by the employer.
Recent events (2)
- — I (S) $2305
- — Z (S) $4610
1910.147 C07 I B
- Issued
- Penalty
- Initial $2765.00 · Current $1383.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(B):Affected employees were not instructed in the purpose and use of the energy control procedure: 171 Tosca Dr. Stoughton MA On or about May 16, 2024, employees were exposed to amputation hazards where the employer had not trained each affected person in the purpose and use of the energy control procedures.
Recent events (2)
- — I (S) $1382.5
- — Z (S) $2765
More inspections in this industry (NAICS 332439)
OKOLONA, KY—2026-06-24
69249 - CONCO INC
GOODYEAR, AZ—2026-06-16
CPX2026XTP177X0009 - INSTITUTE OF GAS TECHNOLOGY DBA GTI ENERGY
WOOSTER, OH—2026-05-14
E-PAK MANUFACTURING, LLC.
CLEVELAND, OH—2026-05-11
MAUSER PACKAGING SOLUTIONS
PEOTONE, IL—2026-05-07
CLEVELAND STEEL CONTAINER CORPORATION
More inspections in MA
WORCESTER, MA—2026-07-10
QUINSIGAMOND COMMUNITY COLLEGE
FITCHBURG, MA—2026-07-10
KELLEY WOOD PRODUCTS, INC.
EVERETT, MA—2026-07-10
HORIZON RETAIL CONSTRUCTION INC
NORTON, MA—2026-07-09
DYNAMIC RESIDENTIAL ROOF MARKETING, LLC
NORTON, MA—2026-07-09
LM GENERAL CONSTRUCTION INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347484974.