Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WEIDENBEIN ENTERPRISES, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of WEIDENBEIN ENTERPRISES, INC. in 600 BUCKSKIN TRAIL, XENIA, OH 45385 (NAICS 238140). OSHA activity number 347487399.

Watch Weidenbein Enterprises, INC. — free Get an email when a new federal OSHA severe-injury report for Weidenbein Enterprises, INC. is published. One employer, no account, unsubscribe in one click.
Site address
600 BUCKSKIN TRAIL
City
XENIA
State
OH
ZIP
45385
Mailing
PO BOX 304, WAPAKONETA, OH 45895
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
10
Ownership type
A

6 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $11292.00 · Current $6750.00 Reduced
29 CFR  1926.20(b)(2):Accident prevention responsibilities. Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.  a) On or about May 16, 2024,  Weidenbein Enterprises, Inc., did not ensure that their accident prevention program included providing for adequate frequent and regular inspections to be conducted by  a competent person designated by Weidenbein Enterprises for the large area scaffold located at the job site located at 600 Buckskin Trail Xenia, OH 45385, in that Weidenbein Enterprises employee(s) were exposed to fall hazards due to improperly installed guardrails on the 6 buck scaffold, in that portions of the scaffold was not fully planked, there was a damaged fixed ladder that was bent used to access and exit the scaffold, and the scaffold erected over 24' and was not tied into the building.
Recent events (2)
  • — I (S) $6750
  • — Z (S) $11292

1926.451 F03

Serious Gravity 10 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.451(f)(3): Use. Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.  a) On or about May 16, 2024, Weidenbein Enterprises, Inc. did not ensure the tubular welded scaffolding system scaffolding components were inspected for visible defects by a designated competent person before each work shift in that the tubular welded  scaffold located on the East Wall of 600 Buckskin Trail Xenia, OH 45385 was not fully planked, had a damaged ladder where the side rails were bent,  the scaffold was not tied into the structure over 20' from ground, and had guardrails missing where employees were laying brick at approximately 18 feet from the ground.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $11292.00 · Current $6750.00 Reduced
29 CFR  1926.451(b)(1):Scaffold platform construction. Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:  (b)(1)(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).  a) On or about May 16, 2024, Weidenbein Enterprises, Inc. did not ensure the 3rd level or buck of the East Wall tubular welded scaffold located at 600 Buckskin Trail Xenia OH 45385 was fully planked near the vertical upright in that employees were working on the third buck of the scaffold around a hole more than 1 inch wide due to not being fully planked, exposing them to trip hazards and a fall hazard of approximately 18 feet.
Recent events (2)
  • — I (S) $6750
  • — Z (S) $11292

1926.451 C01 II

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $11292.00 · Current $0.00 Reduced
29 CFR  1926.451(c)(1)(ii):Criteria for supported scaffolds. Guys, ties, and braces shall be installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and be repeated vertically at locations of horizontal members every 20 feet (6.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91 m) wide. The top guy, tie or brace of completed scaffolds shall be placed no further than the 4:1 height from the top. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other).  a) On or about May 16, 2024, Weidenbein Enterprises, Inc. did not ensure guys, ties, and braces were installed on the tube scaffold that was erected approximately 36 feet or 6 bucks high located at 600 Buckskin Trail Xenia, OH 45385 while employees were laying brick, exposing them to a fall hazard of approximately 18 feet caused by the potential for the scaffold to collapse or tip over.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11292

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $11292.00 · Current $0.00 Reduced
29 CFR  1926.451(g)(1):Fall protection. Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part.  a) On or about May 16, 2024, Weidenbein Enterprises, Inc. did not adequately protect each employee with fall protection while laying brick on the East Wall scaffold located at 600 Buckskin Trail Xenia OH 45385 from fall hazards of approximately 18 feet while retrieving materials through a gap approximately 18 inches wide.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11292

1926.1053 B17

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $11292.00 · Current $0.00 Reduced
29 CFR  1926.1053(b)(17):Fixed ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, or corroded components, shall be withdrawn from service until repaired. The requirement to withdraw a defective ladder from service is satisfied if the ladder is either: (i) Immediately tagged with "Do Not Use" or similar language,  (ii) Marked in a manner that readily identifies it as defective;  a) On or about May 16, 2024, Weidenbein Enterprises, Inc. did not ensure that fixed ladders with defects were removed from service until repaired, in that the fixed ladder installed on the East Wall tube scaffold was bent, exposing employees to a fall height of approximately 18 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11292

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347487399.