DUBLIN, OH —
OSHA Inspection: DARTPOINTS OPERATING COMPANY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of DARTPOINTS OPERATING COMPANY in 565 METRO PLACE SOUTH, STE 300, DUBLIN, OH 43017 (NAICS 518210). OSHA activity number 347487837.
Where did this inspection happen?
- Establishment
- DARTPOINTS OPERATING COMPANY
- Site address
- 565 METRO PLACE SOUTH, STE 300
- City
- DUBLIN
- State
- OH
- ZIP
- 43017
- Mailing
- 78 GLOBAL DR SUITE 100, GREENVILLE, SC 29607
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 518210
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $8067.00 · Current $8067.00
General-duty citation text
29 CFR 1910.147(c)(1):Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. a. On or before May 14, 2024, the employer did not develop and implement an energy control program to protect employees performing servicing and maintenance on equipment.
Recent events (2)
- — I (O) $8067
- — Z (S) $8067
1910.333 A
- Issued
- Abate by
- Penalty
- Initial $8067.00 · Current $8067.00
General-duty citation text
29 CFR 1910.333(a):"General." Safety-related work practices shall be employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work is performed near or on equipment or circuits which are or may be energized. The specific safety-related work practices shall be consistent with the nature and extent of the associated electrical hazards. a. On or before May 14, 2024, for employees who routinely perform work on or near energized parts such as testing, troubleshooting, installing branch circuits, and other tasks in and around the electrical equipment in the data center, neither a flash hazard analysis was conducted to determine the proper protection required nor was a flash protection boundary established to protect employees from shock, arc flash, or arc blast. ABATEMENT NOTE: One method of abatement, among others, includes conducting a flash hazard analysis in compliance with NFPA 70E Standard for Electrical Safety in the Workplace to determine the flash protection boundary and the use of electrical protective equipment as necessary for the specific related hazards of each task.
Recent events (2)
- — I (O) $8067
- — Z (S) $8067
1910.332 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.332(b)(1): Practices addressed in this standard. Employees shall be trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertain to their respective job assignments. a. On or before May 14, 2024, for employees who routinely perform work on or near energized parts such as testing, troubleshooting, installing branch circuits, and other tasks in and around the electrical equipment in the data center, employees were not provided with training on electrical safety related work practices and the potential for arc flash/arc blast.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.137 C02 VIII
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.137(c)(2)(viii): Electrical protective equipment shall be subjected to periodic electrical tests. Test voltages and the maximum intervals between tests shall be in accordance with Table I-4 and Table I-5. a. On or before May 14, 2024, for employees who routinely perform work on or near energized parts such as testing, troubleshooting, installing branch circuits, and other tasks in and around the electrical equipment in the data center, gloves provided for electrical protection were not tested every 6 months as required by Table I-5.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections in this industry (NAICS 518210)
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
GREENVILLE, SC—2026-06-04
77514 - ALLIED UNIVERSAL
LEACHVILLE, AR—2026-05-26
ORIENT OASIS LLC
FAYETTEVILLE, GA—2026-05-22
MICROSOFT CORPORATION
FOREST CITY, NC—2026-05-14
161198 - ANDALE, LLC
More inspections in OH
WELLINGTON, OH—2026-07-16
WHIRLAWAY CORPORATION
WAUSEON, OH—2026-07-16
WATSON WELL DRILLING INC.
SEVEN HILLS, OH—2026-07-15
STONEY ACRES BUILDERS LLC
SEVEN HILLS, OH—2026-07-15
GRB ENTERPRISES LLC
CHILLICOTHE, OH—2026-07-15
KENWORTH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347487837.