Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: THERMOFORMED PLASTICS OF NEW ENGLAND, LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of THERMOFORMED PLASTICS OF NEW ENGLAND, LLC. in 362 HILL STREET, BIDDEFORD, ME 04005 (NAICS 326199). OSHA activity number 347488322.

Watch Thermoformed Plastics OF NEW England, LLC. — free Get an email when a new federal OSHA severe-injury report for Thermoformed Plastics OF NEW England, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
362 HILL STREET
City
BIDDEFORD
State
ME
ZIP
04005
Mailing
362 HILL STREET, BIDDEFORD, ME 04005
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
10
Ownership type
A

4 citations on file for this inspection.

1910.176 B

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3457.00 · Current $1729.00 Reduced
29 CFR 1910.176(b): Material stored in tiers was not stacked, blocked, interlocked, or limited in height so that it was stable and secure against sliding and collapse:  Production floor - Employees were exposed to Ridg-U-Rak slotted warehouse raking that was not secured to the floor.
Recent events (2)
  • — I (S) $1728.5
  • — Z (S) $3457

1910.212 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $3457.00 · Current $1729.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by the point of operation, ingoing nip points, rotating parts, flying chips, and sparks:  Production floor - The ingoing nip points of the thermoplastic unwinder was not guarded to prevent employee contact with the rollers.
Recent events (2)
  • — I (S) $1728.5
  • — Z (S) $3457

1910.1200 E01

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2074.00 · Current $1037.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:  Establishment - The employer's written hazard communication program was insufficient in that it did not include the 16 sections of a Safety Data Sheet (SDS).
Recent events (2)
  • — I (S) $1037
  • — Z (S) $2074

1910.157 E02

Other-than-serious 11 instances 8 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  Establishment - Fire extinguishers throughout the facility were not inspected monthly.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View THERMOFORMED PLASTICS OF NEW ENGLAND, LLC.'s full OSHA safety record →