YORKTOWN HEIGHTS, NY —
OSHA Inspection: PREMIER BUILDING & RENOVATIONS CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PREMIER BUILDING & RENOVATIONS CORP. in 3320 OLD CROMPOND RD., YORKTOWN HEIGHTS, NY 10598 (NAICS 238140). OSHA activity number 347491268.
Where did this inspection happen?
- Establishment
- PREMIER BUILDING & RENOVATIONS CORP.
- Site address
- 3320 OLD CROMPOND RD.
- City
- YORKTOWN HEIGHTS
- State
- NY
- ZIP
- 10598
- Mailing
- 769 FULTON ST., FARMINGDALE, NY 11735
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 7
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 B01
- Issued
- Penalty
- Initial $6857.00 · Current $5575.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): location: scaffold beside mason wall on or about: 5/16/24 a) Employees were engaged in masonry work from a scaffold platform 13'2" above the ground, The platform was not fully decked. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (O) $5575
- — Z (S) $6857
1926.451 E01
- Issued
- Penalty
- Initial $4113.00 · Current $3350.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: location: scaffold beside mason wall on or about: 5/16/24 a) Employees were engaged in masonry work from a tubular welded frame scaffold. The employees were using the walk through frames for access. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (O) $3350
- — Z (S) $4113
1926.451 G01
- Issued
- Penalty
- Initial $6857.00 · Current $5575.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level: location: scaffold beside mason wall on or about: 5/16/24 a) Employees, engaged in masonry work from a scaffold platform 13'2" above the ground, were not provided with adequate fall protection. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (O) $5575
- — Z (S) $6857
1926.54 D
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.54(d):Standard laser warning placards were not posted in areas in which lasers were used: location: scaffold area on or about: 5/16/24 a) Employees were using/working near a laser level while engaged in masonry work. Warning placards were not posted. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238140)
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
LOMPOC, CA—2026-07-10
UNKNOWN EMPLOYER
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
CINCINNATI, OH—2026-07-09
ALL AMERICAN CONCRETE LLC
NEW YORK, NY—2026-07-08
JEY CONSTRUCTIONS WORKS CORP
More inspections in NY
POUGHKEEPSIE, NY—2026-07-13
MARCO BOARD HOUSE, INC.
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CORTLANDT MANOR, NY—2026-07-13
RJW RENOVATIONS, LLC
HEMPSTEAD, NY—2026-07-13
NYSDOCCS NASSAU AREA OFFICE
NIAGARA FALLS, NY—2026-07-10
NTVI FEDERAL INC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347491268.