Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PREMIER BUILDING & RENOVATIONS CORP.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PREMIER BUILDING & RENOVATIONS CORP. in 3320 OLD CROMPOND RD., YORKTOWN HEIGHTS, NY 10598 (NAICS 238140). OSHA activity number 347491268.

Watch Premier Building & Renovations Corp. — free Get an email when a new federal OSHA severe-injury report for Premier Building & Renovations Corp. is published. One employer, no account, unsubscribe in one click.
Site address
3320 OLD CROMPOND RD.
City
YORKTOWN HEIGHTS
State
NY
ZIP
10598
Mailing
769 FULTON ST., FARMINGDALE, NY 11735
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
7
Ownership type
A

4 citations on file for this inspection.

1926.451 B01

Other-than-serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $6857.00 · Current $5575.00 Reduced
29 CFR  1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):  location: scaffold beside mason wall on or about: 5/16/24  a) Employees were engaged in masonry work from a scaffold platform 13'2" above the ground, The platform was not fully decked.   NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
  • — I (O) $5575
  • — Z (S) $6857

1926.451 E01

Other-than-serious Gravity 1 1 instance 6 exposed
Issued
Penalty
Initial $4113.00 · Current $3350.00 Reduced
29 CFR  1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access:   location: scaffold beside mason wall on or about: 5/16/24  a) Employees were engaged in masonry work from a tubular welded frame scaffold.  The employees were using the walk through frames for access.    NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
  • — I (O) $3350
  • — Z (S) $4113

1926.451 G01

Other-than-serious Gravity 5 1 instance 6 exposed
Issued
Penalty
Initial $6857.00 · Current $5575.00 Reduced
29 CFR  1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level:  location: scaffold beside mason wall on or about: 5/16/24  a) Employees, engaged in masonry work from a scaffold platform 13'2" above the ground, were not provided with adequate fall protection.   NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
  • — I (O) $5575
  • — Z (S) $6857

1926.54 D

Other-than-serious 1 instance 7 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.54(d):Standard laser warning placards were not posted in areas in which lasers were used:  location: scaffold area on or about: 5/16/24  a) Employees were using/working near a laser level while engaged in masonry work. Warning placards were not posted.  NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347491268.