NORTHUMBERLAND, PA —
OSHA Inspection: SPLASH MAGIC LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SPLASH MAGIC LLC in 213 ASPEN LANE, NORTHUMBERLAND, PA 17857 (NAICS 721211). OSHA activity number 347511016.
Where did this inspection happen?
- Establishment
- SPLASH MAGIC LLC
- Site address
- 213 ASPEN LANE
- City
- NORTHUMBERLAND
- State
- PA
- ZIP
- 17857
- Mailing
- 213 ASPEN LANE, NORTHUMBERLAND, PA 17857
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 721211
- Employees
- 50
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.132 D01
- Issued
- Abate by
- Penalty
- Initial $8067.00 · Current $5245.00 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which necessitated the use of personal protective equipment: a) 213 Aspen Lane Northumberland, PA 17857- On or about May 30, 2024, employees were exposed to chemical hazards without the employer performing a hazard assessment of their work tasks. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $5245
- — Z (S) $8067
1910.133 A01
- Issued
- Abate by
- Penalty
- Initial $8067.00 · Current $5245.00 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment: a) Pool Pump Area- On or about May 30, 2024, employees were exposed to chemical burn hazards from the use of corrosive chemicals such as but not limited to sodium hypochlorite without the use of protective eye equipment. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $5245
- — Z (S) $8067
1910.138 A
- Issued
- Abate by
- Penalty
- Initial $6453.00 · Current $4190.00 Reduced
General-duty citation text
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes: a) Pool Pump Area- On or about May 30, 2024, employees were exposed to chemical burn hazards from the use of corrosive chemicals such as but not limited to sodium hypochlorite without the use of appropriate hand protection to prevent chemical burns. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $4190
- — Z (S) $6453
1910.151 C
- Issued
- Abate by
- Penalty
- Initial $11292.00 · Current $7330.00 Reduced
General-duty citation text
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) Pool Pump Area- On or about May 30, 2024, employees were exposed to chemical burn hazards from the use of corrosive chemicals such as but not limited to sodium hypochlorite without available facilities for quick drenching or flushing. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $7330
- — Z (S) $11292
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $8067.00 · Current $5245.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Store Area- On or about May 30, 2024, employees were exposed to struck-by hazards from powered industrial truck operators who were not trained or evaluated for their ability to safely operate a powered industrial truck. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $5245
- — Z (S) $8067
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $8067.00 · Current $5245.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) 213 Aspen Lane Northumberland, PA 17857- On or about May 30, 2024, employees were exposed to chemical burn hazards from the use of corrosive chemicals such as but not limited to sodium hypochlorite without a written hazard communication program. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $5245
- — Z (S) $8067
1910.1200 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use: a) 213 Aspen Lane Northumberland, PA 17857- On or about May 30, 2024, employees were exposed to chemical burn hazards from the use of corrosive chemicals such as but not limited to sodium hypochlorite without an available safety data sheet. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) 213 Aspen Lane Northumberland, PA 17857- On or about May 30, 2024, employees were exposed to chemical burn hazards from the use of corrosive chemicals such as but not limited to sodium hypochlorite without hazard communication training. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.332 B01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: a) 213 Aspen Lane Northumberland, PA 17857- On or about May 30, 2024, employees are exposed to electrical shock hazards from repairing broken electrical outlets without proper training. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 721211)
MAYVILLE, MI—2026-06-29
THE FOWLER CENTER FOR OUTDOOR LEARNING
STURGEON BAY, WI—2026-05-28
HARBOUR VILLAGE CAMPGROUND AND WATER PARK
SHAVER LAKE, CA—2026-05-26
BASS LAKE HOSPITALITY, LLC
STURGEON BAY, WI—2026-05-18
HARBOUR VILLAGE CAMPGROUND AND WATER PARK
ROCKAWAY BEACH, OR—2026-05-12
317744116 - SN VENTURES LLC
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347511016.