On , OSHA opened a planned safety inspection of JC CONTRACTING LTD in 2335 S HOLMAN CIR, LAKEWOOD, CO 80228 (NAICS 238160). OSHA activity number 347520603.
Where did this inspection happen?
- Establishment
- JC CONTRACTING LTD
- Site address
- 2335 S HOLMAN CIR
- City
- LAKEWOOD
- State
- CO
- ZIP
- 80228
- Mailing
- 1050 S PIERCE ST. LOT 6, LAKEWOOD, CO 80226
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $4839.00 · Current $4839.00
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) On or before 6/1/24, the employer did not ensure that employees utilized fall protection. Employees were replacing the roof of a two-story single-family home without utilizing fall protection. This condition exposed employees to fall hazards of 9 feet and 18 feet.
Recent events (1)
- — Z (S) $4839
1926.1053 B01
- Issued
- Abate by
- Penalty
- Initial $4839.00 · Current $4839.00
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: (a) On or before 6/1/2024, the employer did not ensure that the extension ladder used to access the second story roof from the ground extended at least three feet past the eave of the roof. This condition exposed employees to a fall hazard of 18 feet.
Recent events (1)
- — Z (S) $4839
More inspections in this industry (NAICS 238160)
FAIRVIEW, TN—2026-07-16
MARVIN PINERA
CARSON CITY, NV—2026-07-16
UNKNOWN/INVALID ESTABLISHMENT
BANNOCKBURN, IL—2026-07-16
ROOFING H.P. LLC
LOXLEY, AL—2026-07-16
CARLOS CHE
BALTIMORE, MD—2026-07-16
VAL CONSTRUCTION INC
More inspections in CO
BROOMFIELD, CO—2026-07-16
WAVELYNX TECHNOLOGIES LLC
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347520603.