Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BURUCA CONSTRUCTION COMPANY, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BURUCA CONSTRUCTION COMPANY, LLC in 621 CELESTE STREET, NEW ORLEANS, LA 70130 (NAICS 238320). OSHA activity number 347526071.

Watch Buruca Construction Company, LLC — free Get an email when a new federal OSHA severe-injury report for Buruca Construction Company, LLC is published. One employer, no account, unsubscribe in one click.
Site address
621 CELESTE STREET
City
NEW ORLEANS
State
LA
ZIP
70130
Mailing
4834 CORSICA PLACE, NEW ORLEANS, LA 70129
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238320
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.416 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $4839.00 · Current $4839.00
29 CFR  1926.416(a)(1): Employee(s) were permitted to work in proximity to an electric power circuit that the employee could contact in the course of work and was not protected against electric shock by de-energizing the circuit and grounding it or by guarding it effectively by insulation or other means:  a) On or about June 6, 2024, on the south side of the jobsite, employees engaged in painting operations of the structure worked within an aerial lift in close proximity to electric power circuits that were not protected against electrical shock hazards.
Recent events (1)
  • — Z (S) $4839

1926.453 B02 V

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $4839.00 · Current $4839.00
29 CFR 1926.453(b)(2)(v): A body belt with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift:  a) On or about June 6, 2024, on the south side of the jobsite, employees engaged in painting operations of the structure utilized an aerial lift without adequate fall protection, by not being anchored in the lift, at heights greater than six (6) feet above the ground.