OSHA Inspection: JLS AUTOMATION

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of JLS AUTOMATION in 650 PRECISION COURT, MIAMISBURG, OH 45342 (NAICS 333993). OSHA activity number 347553265.

Watch JLS Automation — free Get an email when a new federal OSHA severe-injury report for JLS Automation is published. One employer, no account, unsubscribe in one click.
Establishment
JLS AUTOMATION
Site address
650 PRECISION COURT
City
MIAMISBURG
State
OH
ZIP
45342
Mailing
20 INNOVATION DRIVE, YORK, PA 17402
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333993
Employees
180
Ownership type
A

3 citations on file for this inspection.

1910.147 C07 III B

Other-than-serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $14518.00 · Current $7250.00 Reduced
1910.147(c)(7)(iii)(B)  Additional retraining shall also be conducted whenever a periodic inspection under paragraph (c)(6) of this section reveals, or whenever the employer has reason to believe that there are deviations from or inadequacies in the employee's knowledge or use of the energy control procedures.  a) On or about May 14 2024, the employer did not ensure each employee was retrained when the employer had reason to believe deviations in the employee's knowledge or use of employer's energy control procedures occurred.
Recent events (3)
  • — F (O) $7250
  • — C (S) $14518
  • — Z (S) $14518

1910.147 F01

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $14518.00 · Current $0.00 Reduced
29 CFR  1910.147(f)(1):Testing or positioning of machines, equipment or components thereof. In situations in which lockout or tagout devices must be temporarily removed from the energy isolating device and the machine or equipment energized to test or position the machine, equipment or component thereof, the following sequence of actions shall be followed:  (i) Clear the machine or equipment of tools and materials in accordance with paragraph (e)(1) of this section;  (ii) Remove employees from the machine or equipment area in accordance with paragraph (e)(2) of this section;   a) On or about May 14 2024, JLS Automation did not ensure that the machine energy isolation specific procedures were utilized by each authorized employee installing the Retail Ready Case Erector and Sealer on the Combi line in that the line was still in operation during installation.
Recent events (3)
  • — F (S) $0
  • — C (S) $14518
  • — Z (S) $14518

1910.147 F02 I

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6222.00 · Current $0.00 Reduced
29 CFR  1910.147(f)(2)(i):Whenever outside servicing personnel are to be engaged in activities covered by the scope and application of this standard, the on-site employer and the outside employer shall inform each other of their respective lockout or tagout procedures.  a.) On or about May 14, 2024, as an outside servicing contractor, JLS Automation did not ensure that Killer Brownie received a copy of their lockout tagout procedures prior to JLS employees installing and testing the retail ready case erector and sealer  on the Combi line.
Recent events (3)
  • — F (S) $0
  • — C (S) $6222
  • — Z (S) $6222