Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SUTTON TRANSPORT, INC. - ST. LOUIS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SUTTON TRANSPORT, INC. - ST. LOUIS in 100 MARION STREET, SAINT LOUIS, MO 63104 (NAICS 484230). OSHA activity number 347573586.

Watch Sutton Transport, INC. - ST. Louis — free Get an email when a new federal OSHA severe-injury report for Sutton Transport, INC. - ST. Louis is published. One employer, no account, unsubscribe in one click.
Site address
100 MARION STREET
City
SAINT LOUIS
State
MO
ZIP
63104
Mailing
100 MARION STREET, SAINT LOUIS, MO 63104
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
484230
Employees
72
Ownership type
A

4 citations on file for this inspection.

1910.305 A02 II

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $11524.00 · Current $6914.00 Reduced
29 CFR  1910.305(a)(2)(ii):Temporary wiring was not removed immediately upon completion of the project or purpose for which the wiring was installed.  A pump which was affixed to the wall at the rear of the facility was powered by an extension cord which was wrapped around a metal beam and plugged into an outlet connected to emergency lighting.   At 100 Marion St, St Louis, MO, 63104, on June 26 and at times prior thereto, employees were exposed to electrical hazards from  a pump which was affixed to the wall at the rear of the facility was powered by an extension cord which was wrapped around a metal beam and plugged into an outlet connected to emergency lighting.
Recent events (2)
  • — I (S) $6914.4
  • — Z (S) $11524

1910.305 A02 XI

Serious Gravity 5 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(a)(2)(xi):Cable assemblies and flexible cords and cables were not supported in place at intervals that ensure that they will be protected from physical damage. Support was not in the form of staples, cables ties, straps, or similar type fittings installed so as not to cause damage.  At 100 Marion St, St Louis, MO, 63104, on June 26 and at times prior thereto employees were exposed to electrical hazards related to an extension cord which was in use to power a wall mounted pump.  The cord was hanging from the outlet above an emergency light, dropping down and wrapping around a steel beam before being plugged into the wall mounted pump.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 F02

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.303(f)(2):Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.  At 100 Marion St, St Louis, MO, 63104, on June 26 and at times prior thereto, employees were exposed to electrical hazards from an electrical panel whose circuit breakers were not labeled to indicate what circuit it protected against overcurrent.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(h)(1):Employers did not provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new chemical hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information was not available through labels and safety data sheets.  At 100 Marion St, St Louis, MO, 63104, on June 26 and at times prior thereto, employees were exposed to chemical hazards from a large container of DEF located at the rear of the facility which was not labeled to indicate its contents.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347573586.