Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: WOLF M CONSTRUCTION LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WOLF M CONSTRUCTION LLC in 2835 S MAIN STREET, RICE LAKE, WI 54868 (NAICS 238160). OSHA activity number 347589913.

Watch Wolf M Construction LLC — free Get an email when a new federal OSHA severe-injury report for Wolf M Construction LLC is published. One employer, no account, unsubscribe in one click.
Site address
2835 S MAIN STREET
City
RICE LAKE
State
WI
ZIP
54868
Mailing
4023 N 42ND STREET, MILWAUKEE, WI 53216
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.501 B10

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4839.00 · Current $4839.00
29 CFR  1926.501(b)(10):Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system:  (a) Commercial building rooftop, various locations; On or about June 27, 2024, and dates prior, employees working from a low-slope roof were not protected from falls while engaged in roofing system replacement activities at approximate heights ranging between 12-foot, 9-inches to 20-feet, 9 inches above ground-level.
Recent events (1)
  • — Z (S) $4839

1926.1053 B01

Serious Gravity 5 2 instances 4 exposed
Issued
Penalty
Initial $2765.00 · Current $2765.00
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:  (a) Commercial building, lower roof; On or about June 27, 2024, and dates prior, the side rails of a Werner model D1220-2 aluminum extension ladder, used by employees to gain access to the lower level rooftop, did not extend at least 3-feet above the landing surface, was not secured to prevent displacement, and grab handles were not provided.    (b) Commercial building, upper roof; On or about June 27, 2024, and dates prior, the side rails of a multi-position aluminum ladder, set-up as an extension ladder, and used by employees to gain access to the upper level rooftop, did not extend at least 3-feet above the landing surface, was not secured to prevent displacement, and grab handles were not provided.
Recent events (1)
  • — Z (S) $2765

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347589913.