NEVADA, TX —
OSHA Inspection: WESTERN STATES METAL ROOFING
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of WESTERN STATES METAL ROOFING in 15023 COUNTY ROAD 545, NEVADA, TX 75173 (NAICS 332312). OSHA activity number 347603433.
Where did this inspection happen?
- Establishment
- WESTERN STATES METAL ROOFING
- Site address
- 15023 COUNTY ROAD 545
- City
- NEVADA
- State
- TX
- ZIP
- 75173
- Mailing
- 15023 COUNTY ROAD 545, NEVADA, TX 75173
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 6
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.22 D01
- Issued
- Penalty
- Initial $6222.00 · Current $3733.00 Reduced
General-duty citation text
29 CFR 1910.22(d)(1): The employer did not ensure that walking-working surfaces are inspected, regularly and as necessary, and maintained in a safe condition On or about July 9, 2024 employees were exposed to injury from tripping hazards on the walking working surfaced of the production area. A power cord leading to both panel machines SSQ2U and Schlebach Quadr-OC were laying on the walking working surface of production shop and presented a tripping hazard for employees working on production floor.
Recent events (2)
- — I (S) $3733.2
- — Z (S) $6222
1910.303 G02 I
- Issued
- Abate by
- Penalty
- Initial $10372.00 · Current $6223.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of On or about July 9, 2024 employees were exposed to electrical hazards while working around a 480V electrical outlet which was equipped with a guard that was broken and unsecured to the electrical junction box, which could allow for accidental contact.
Recent events (2)
- — I (S) $6223.2
- — Z (S) $10372
More inspections in this industry (NAICS 332312)
WYOMING, MI—2026-07-16
R&M FABRICATION LLC
TRUSSVILLE, AL—2026-07-16
ALL SOUTH STEELWORX, LLC
NORTH BRANCH, MN—2026-07-15
111603 - BROWN HAWK LLC DBA NORTHERN LIGHTS STEEL FAB
VAN BUREN, AR—2026-07-14
MILLAR PARTNERS, LLC
CLANTON, AL—2026-07-14
C & S CANOPY, INC.
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347603433.