Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PLATINUM ROOFING & EXTERIOR LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PLATINUM ROOFING & EXTERIOR LLC in 10812 HEATHER RIDGE CIR, ORLANDO, FL 32817 (NAICS 238160). OSHA activity number 347633877.

Watch Platinum Roofing & Exterior LLC — free Get an email when a new federal OSHA severe-injury report for Platinum Roofing & Exterior LLC is published. One employer, no account, unsubscribe in one click.
Site address
10812 HEATHER RIDGE CIR
City
ORLANDO
State
FL
ZIP
32817
Mailing
4451 NORTHWEST ALSACE AVENUE, PORT SAINT LUCIE, FL 34983
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $4839.00 · Current $2903.00 Reduced
29 CFR  1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) On or about July 22, 2024, at 10812 Heather Ridge Cir Orlando Fl 32817: employees were exposed to a 23 foot fall hazard while engaged in roofing activities, in that, fall protection was not used.
Recent events (2)
  • — I (S) $2903.4
  • — Z (S) $4839

1926.1053 B01

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $4610.00 · Current $2766.00 Reduced
29 CFR  1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder.    a) On or about July 22, 2024, at 10812 Heather Ridge Cir Orlando Fl 32817: employees was exposed to an approximate 23 an extension ladder being used to access the worksite was extended to the maximum allowed per manufacture specifications, however they did not provide a grasping device to assist employees in mounting and dismounting the ladder, thus exposing employees to fall hazards of approximately 23ft.
Recent events (2)
  • — I (S) $2766
  • — Z (S) $4610

1926.503 B01

Other-than-serious 1 instance 25 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.503(b)(1):The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.  a) On or about July 22, 2024, at the worksite: the employer did not prepare and maintain a written fall protection training certification for employees exposed to fall hazards of 23 feet and above while installing roofing materials.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347633877.