Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SOUTH COAST ARCHITECTURAL WOOD WORKING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOUTH COAST ARCHITECTURAL WOOD WORKING INC. in 6312 SHORTCUT ROAD, MOSS POINT, MS 39563 (NAICS 337212). OSHA activity number 347666802.

Watch South Coast Architectural Wood Working INC. — free Get an email when a new federal OSHA severe-injury report for South Coast Architectural Wood Working INC. is published. One employer, no account, unsubscribe in one click.
Site address
6312 SHORTCUT ROAD
City
MOSS POINT
State
MS
ZIP
39563
Mailing
6312 SHORTCUT ROAD, MOSS POINT, MS 39563
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337212
Employees
8
Ownership type
A

3 citations on file for this inspection.

1910.219 F03

Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $2074.00 · Current $1244.00 Reduced
29 CFR  1910.219(f)(3): Sprocket wheels and chains that were seven (7) or less feet from the floor or platform were not enclosed:  a) Shop- On or about July 11, 2024, the employer did not ensure that the sprocket wheel and chain on the Mar-Bel pinch roller were guarded, exposing employees to amputation hazards.
Recent events (2)
  • — I (S) $1244.4
  • — Z (S) $2074

1910.242 B

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2765.00 · Current $1659.00 Reduced
29 CFR  1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment:  (a)Cut Shop - On or about July 11, 2024, air pressure was used to dry and clean material cut from multiple pieces of equipment in the shop, the compressor was set at 108 p.s.i., exposing employees to eye injuries.
Recent events (2)
  • — I (S) $1659
  • — Z (S) $2765

1910.303 G01

Serious Gravity 1 2 instances 4 exposed
Issued
Penalty
Initial $2074.00 · Current $1244.00 Reduced
29 CFR  1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  (a) Shop- On or about July 11, 2024, the employer did not ensure there was a 3-feet clearance in front of the electrical panels there was excess equipment and material placed in front of the panel, exposing the employees to electrical hazards.
Recent events (2)
  • — I (S) $1244.4
  • — Z (S) $2074

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 347666802.